Fault code
Meaning of the fault code
(Hex)
possible reason for fault detection
34
S.C. to battery voltage or O.C. at turbine
speed input
TCU measures a voltage higher than
7.00V at speed input pin
· Cable is defective and is contacted to
vehicle battery voltage
· Cable has no connection to TCU
·Speed sensor has an internal defect
· Connector pin is contacted to battery
voltage or has no contact
35
S.C. to ground at turbine speed input
TCU measures a voltage less than 0.45V
at speed input pin
· Cable/connector is defective and is
contacted to vehicle ground
· Speed sensor has an internal defect
36
Logical error at turbine speed input
TCU measures a turbine speed over a
threshold and at the next moment the
measured speed is zero
· Cable/connector is defective and has
bad contact
· Speed sensor has an internal defect
·Sensor gap has the wrong size
37
S.C. to battery voltage or O.C. at internal
speed input
TCU measures a voltage higher than
7.00V at speed input pin
· Cable is defective and is contacted to
vehicle battery voltage
· Cable has no connection to TCU
·Speed sensor has an internal defect
· Connector pin is contacted to battery
voltage or has no contact
38
S.C. to ground at turbine speed input
TCU measures a voltage less than 0.45V
at speed input pin
· Cable/connector is defective and is
contacted to vehicle ground
· Speed sensor has an internal defect
39
Logical error at internal speed input
TCU measures a internal speed over a
threshold and at the next moment the
measured speed is zero
· Cable/connector is defective and has
bad contact
· Speed sensor has an internal defect
·Sensor gap has the wrong size
3A
S.C. to battery voltage or O.C. at output
speed input
TCU measures a voltage higher than
12.5V at speed input pin
· Cable is defective and is contacted to
battery voltage
· Cable has no connection to TCU
·Speed sensor has an internal defect
· Connector pin is contacted to battery
voltage or has no contact
※ Some fault codes are not applied to this machine.
Reaction of the TCU
OP mode : Substitute clutch
control
If a failure is existing at
output speed,
TCU shifts to neutral
OP mode : Limp home
OP mode : Substitute clutch
control
If a failure is existing at
output speed,
TCU shifts to neutral
OP mode : Limp home
OP mode : Substitute clutch
control
If a failure is existing at
output speed,
TCU shifts to neutral
OP mode : Limp home
OP mode : Substitute clutch
control
OP mode : Substitute clutch
control
OP mode : Substitute clutch
control
Special mode for gear
selection
OP mode : S u b s t i t u t e
clutch control
If a failure is existing at
turbine speed,
TCU shifts to neutral
OP mode : Limp home
3-60
Possible steps to repair
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor
※
This fault is reset after power up of
TCU
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor
·
Check the sensor gap
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor
·
Check the sensor gap
※
This fault is reset after power up of
TCU
·
Check the cable from TCU to the
sensor
·
Check the connectors
·
Check the speed sensor