6. ELECTRIC PARKING, PILOT CUT OFF CIR
6. ELECTRIC
PARKING, PILOT CUT OFF CIRCUIT
1) 1)
OPERATING FLOW
OPERATING FLOW
(1) (1)
Parking OFF
Parking OFF
Fuse box [CN-39 (41)]
(2) (2)
Parking ON
Parking ON
Fuse box [CN-39 (41)]
Parking brake applied [By spring force]
(3) (3)
Pilot cut off ON
Pilot cut off ON
Fuse box [CN-39 (41)]
I/conn [CN-05 (11)]
Pilot cut off released
(4) (4)
Pilot cut off OFF
Pilot cut off OFF
Fuse box [CN-39 (41)]
Pilot cut off applied
2)
2)
CHECK POINT
CHECK POINT
Engine
Running
※ GND : Ground
Parking switch OFF
OFF
ON
Parking switch ON
Pilot cut off switch ON
I/conn [CN-12 (12)]
Pilot cut off switch OFF
Key switch
① - GND (parking switch input)
② - GND (parking switch output)
③ - GND (pilot cut off switch input)
ON
④ - GND (pilot cut off switch output)
⑤ - GND (parking solenoid)
⑥ - GND (pilot cut off solenoid)
CUIT
[CS-17 (5)→(4)]
I/conn [CN-12 (13)]
Parking solenoid ON (activated)
Parking brake released (by hydraulic pressure)
[CS-17 (2)→(1)]
Parking solenoid [CN-71] OFF
Pilot cut off switch [CS-4 (5) → (4)]
Pilot cut off solenoid ON [CN-68] (activate)
Pilot cut off solenoid [CN-68] OFF
Check point
7-17
I/conn [CN-05 (14)]
T/M control unit [CN-157 (21)]
Voltage
20~25V