Syntax
history-record keep-time keep-time
undo history-record keep-time
Default
The history records in an NQA operation are kept for 120 minutes.
Views
Any NQA operation view
Default command level
2: System level
Parameters
keep-time: Specifies how long the history records can be saved. The time is in the range of 1 to 1440
minutes.
Usage guidelines
When an NQA operation completes, the timer starts. All records are removed when the lifetime is
reached.
Examples
# Configure the lifetime of the history records in an NQA operation as 100 minutes.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] history-record keep-time 100

history-record number

Use history-record number to configure the maximum number of history records that can be saved in an
NQA operation.
Use undo history-record number to restore the default.
Syntax
history-record number number
undo history-record number
Default
The maximum number of records that can be saved in an NQA operation is 50.
Views
Any NQA operation view
Default command level
2: System level
Parameters
number: Specifies the maximum number of history records that can be saved in an NQA operation. The
value is in the range of 0 to 50.