H3C SR6600 Command Reference Manual page 76

Network management and monitoring command reference
Hide thumbs Also See for SR6600:
Table of Contents

Advertisement

Usage guidelines
Configure the command on the NQA server for the UDP jitter, UDP echo, and voice operations only.
The IP address and port number must be consistent with those configured on the NQA client and must be
different from those of an existing UDP listening service.
The IP address must be that of an interface on the NQA server. Otherwise, the configuration becomes
invalid.
Examples
# Configure a UDP listening service to enable the NQA server to listen and respond on the IP address
169.254.10.2 and port 9000.
<Sysname> system-view
[Sysname] nqa server udp-echo 169.254.10.2 9000
Related commands
nqa server enable
display nqa server status
68