Tos - H3C SR6600 Command Reference Manual

Network management and monitoring command reference
Hide thumbs Also See for SR6600:
Table of Contents

Advertisement

Views
DLSw operation view, DNS operation view, FTP operation view, HTTP operation view, ICMP echo
operation view, SNMP operation view, TCP operation view, UDP echo operation view, UDP jitter
operation view, voice operation view
Default command level
2: System level
Parameters
interval: Specifies the interval in minutes for collecting statistics for an NQA operation, in the range of 1
to 35791394.
Usage guidelines
NQA collects the result statistics within the specified interval in a statistics group. The statistics form a
statistics group. To view information about the statistics groups, use the display nqa statistics command.
This command is not available for the DHCP operation.
Examples
# Configure the interval for collecting the test result statistics of the ICMP echo operation as 2 minutes.
<Sysname> system-view
[Sysname] nqa entry admin test
[Sysname-nqa-admin-test] type icmp-echo
[Sysname-nqa-admin-test-icmp-echo] statistics interval 2

tos

Use tos to specify the ToS value in the IP packet header of probe packets.
Use undo tos to restore the default.
Syntax
tos value
undo tos
Default
The ToS value in the IP packet header of probe packets is 0.
Views
DLSw operation view, DNS operation view, FTP operation view, HTTP operation view, ICMP echo
operation view, SNMP operation view, TCP operation view, UDP echo operation view, UDP jitter
operation view, voice operation view
Default command level
2: System level
Parameters
value: Specifies the ToS value in the IP packet header of probe packets, in the range of 0 to 255.
Examples
# Configure the ToS value in an IP packet header of probe packets as 1.
<Sysname> system-view
[Sysname] nqa entry admin test
61