Interface modules The SR6600/SR6600-X router supports hot swapping of interface modules. NOTE: The LPU, MPU, and router compatibility matrixes vary by Comware system. For more information, see "Compatibility matrixes." HIMs HIM-8FE (RT-HIM-8FE-H3) The HIM-8FE is a 10Base-T/100Base-TX Fast Ethernet (FE) interface module used by a router to communicate with a LAN.
LEDs Table 1 LED description LED status Description No link is present or the cable is faulty. Steady yellow A 10 Mbps link is present. Flashing yellow Data is being received or transmitted at 10 Mbps. Steady green A 100 Mbps link is present. Flashing green Data is being received or transmitted at 100 Mbps.
Page 7
Front panels Figure 2 Front panel of HIM-8GBE (1) GE port (2) GE port status LED (3) Captive screw (4) Ejector lever Figure 3 Front panel of HIM-4GBE (1) Captive screw (2) GE port (3) GE port status LED (4) Ejector lever LEDs Table 3 LED description LED status...
Interface specifications Table 4 Interface specifications Item Specification Connector type RJ-45 • HIM-4GBE: 4 Number of interfaces • HIM-8GBE: 8 Interface standards 802.3, 802.3u, 802.3ab Interface type Auto MDI/MDI-X Cable type Straight-through/crossover Ethernet cable Transmission distance 100 m (328.08 ft) •...
Page 9
Front panels Figure 4 Front panel of HIM-4GBP (1) Captive screw (2) SFP port (3) SFP port status LED (4) Ejector lever Figure 5 Front panel of HIM-8GBP (1) Captive screw (2) SFP port (3) SFP port status LED (4) Ejector lever LEDs Table 5 LED description LED status...
Page 10
Prepare the transceiver modules yourself as required. H3C recommends that you use H3C SFP transceiver modules for the device. H3C does not guarantee the compatibility of SFP transceiver modules from other vendors with the device. The device reports an alarm when non-H3C SFP transceiver modules are installed.
HIM-1EXP (RT-HIM-1EXP-H3) The HIM- 1 EXP is a 1-port 10 GE transceiver module. It provides one 10-Gigabit Small Form-Factor Pluggable (XFP) port and supports switchover between LAN/WAN PHY modes. A LED is provided on the front panel to show the operation state. Front panel Figure 6 Front panel (1) Captive screw...
• The operating mode configuration takes effect only after you hot-swap the interface module or reboot the device. H3C recommends that you remove and insert the module to bring the configuration into effect. The operating mode configuration takes effect for all the interfaces on the interface module.
Page 13
Front panels Figure 7 Front panel of HIM-CL1P (1) SFP port carrier signal LED (LINK/ACT) (2) SFP port loopback/alarm LED (LP/AL) of SFP port (3) SFP port (4) Captive screw (5) Ejector lever Figure 8 Front panel of HIM-CL2P (1) SFP port carrier signal LED (LINK/ACT) (2) SFP port loopback/alarm LED (LP/AL) (3) SFP port (4) Captive screw...
Interface specifications Table 10 Interface specifications Item Specification Connector type SFP/LC • HIM-CL1P: 1 Number of interfaces • HIM-CL2P: 2 Interface standards SONET OC-3/SDH STM-1 Interface speed 155.52 Mbps Ultra-long Type Short distance Medium distance Long distance distance Optical transmit Min.
Page 15
Supports three operating modes that can be configured at the CLI: CPOS E3, CPOS T3, or POS • (155 Mbps). The configuration of the operating mode can take effect only after you hot-plug the interface module • or reboot the device. It is recommended to remove and insert the module to bring the configuration into effect.
Page 16
LEDs Table 11 LED description Status Description No link is present. LINK/ACT A 155.52 Mbps link is present. (Green) Flashing The SFP port is receiving or sending data at 155.52 Mbps. No loopback or alarm exists. LP/AL The interface is in loopback state. (Yellow) Flashing There is a minimum of one alarm.
HIM-MSP2P (RT-HIM-MSP2P-H3)/HIM-MSP4P (RT-HIM-MSP4P-H3) The HIM-MSP2P/HIM-MSP4P is a high-speed OC-3/STM- 1 (155 Mbps) and OC- 1 2/STM-4 (622 Mbps) non-channelized POS interface module. The HIM-MSP2P/HIM-MSP4P supports PPP, Frame Relay, and HDLC at the data link layer and IP at the network layer. When using the HIM-MSP2P/HIM-MSP4P, follow these guidelines: You can use the card-mode command to configure the interface module to operate in OC-3/STM- 1 •...
Page 18
Figure 12 Front panel (1) Captive screw (2) Ejector lever (3) SFP port carrier signal LED (LINK/ACT) (4) SFP port loopback/alarm LED (LP/AL) (5) SFP port 3 (155 Mbps) or SFP port 1 (622 Mbps) (6) SFP port 2 (155 Mbps) or SFP port 0 (622 Mbps) (7) SFP port 1 (155 Mbps) (8) SFP port 0 (155 Mbps) LEDs...
Page 20
Front panel Figure 13 Front panel of HIM-PS1P (1) Captive screw (2) Ejector lever (3) SFP port carrier signal LED (LINK/ACT) (4) SFP port loopback/alarm LED (LP/AL) (5) SFP port (2.5 Gbps) LEDs Table 15 LED description Status Description No link is present. LINK/ACT A 2488.32 Mbps link is present.
Item Specification Receiving sensitivity –18.0 dBm –18.0 dBm –27.0 dBm –28.0 dBm Overload optical power –3.0 dBm 0.0 dBm –9.0 dBm –8.0 dBm Central wavelength 1310 nm 1310 nm 1310 nm 1550 nm Max. transmission 40 km (24.86 80 km (49.71 2 km (1.24 miles) 15 km (9.32 miles) distance...
Page 22
Front panels Figure 14 Front panel of HIM-AL1P (1) Captive screw (2) Ejector lever (3) SFP port (4) SFP port carrier signal LED (LINK/ACT) (5) SFP port loopback/alarm LED (LP/AL) Figure 15 Front panel of HIM-AL2P (1) Captive screw (2) Ejector lever (3) SFP port (4) SFP port carrier signal LED (LINK/ACT) (5) SFP port loopback/alarm LED (LP/AL)
Status Description The port is in loopback state. Flashing There is a minimum of one alarm. Interface specifications Table 18 Interface specifications Item Specification Connector type SFP/LC • HIM-AL1P: 1 Number of interfaces • HIM-AL2P: 2 Interface standards SONET OC-3C/SDH STM-1 Interface speed 155.52 Mbps Ultra-long...
Front panel Figure 16 Front panel (1) Captive screw (2) Ejector lever (3) PASSTHRU LED of the MAC RPR node (4) WRAP LED of MAC RPR node (5) MAC MATE interface LED (6) STEER LED of the MAC RPR node (7) External SFP port of the MAC RPR node (8) MAC external SFP port carrier signal LED (LINK/ACT) (9) MAC external SFP port loopback/alarm LED (LP/AL)
Interface specifications Table 20 Interface specifications Item Specification Connector type SFP/LC Number of interfaces • SONET STS-48 Interface standards • SDH STM- 1 6 Interface speed 2488.32 Mbps Medium Ultra-long Type Short distance Long distance distance distance Optical transmit Min. –10.0 dBm –5.0 dBm –2.0 dBm...
Page 26
Front panel Figure 17 Front panel (1) Captive screw (2) SFP port (3) Ejector lever (4) SFP port carrier signal LED (LINK/ACT) LEDs Table 21 LED description Status Description No link is present. LINK/ACT (0 to A 1000 Mbps link is present. GE-1000Base- Data is being transmitted or received at 1000 (Green)
Item Specification Central wavelength 850 nm 1310 nm 1310 nm 1550 nm 1550 nm 40 km 0.55 km (0.34 10 km (6.21 40 km 70 km (43.50 Max. transmission distance (24.86 miles) miles) (24.86 miles) miles) miles) 9/125 62.5/125 μm 9/125 μm 9/125 μm μm...
Page 28
To switch the interface type of a HIM-TS8P, use the port-type switch command. To switch the POS interface speed of a HIM-TS8P, use the speed command in POS interface view. For more information about the port-type switch and speed commands, see H3C SR6600/SR6600-X Routers Interface Command Reference.
Page 29
Item Specification Ethernet_II Frame format Ethernet_SNAP Short Medium Long Ultra-long Type Long distance distance distance distance distance Optical transmit Min. –9.5 dBm –9 dBm -–2 dBm –4 dBm –4 dBm power Max. 0 dBm –3 dBm 5 dBm 1 dBm 2 dBm Receiving sensitivity –17 dBm...
Item Specification Receiving sensitivity –28.0 dBm –28.0 dBm –28.0 dBm Overload optical power –8.0 dBm –8.0 dBm –8.0 dBm Central wavelength 1310 nm 1310 nm 1550 nm Max. transmission distance 15 km (9.32 miles) 40 km (24.86 miles) 80 km (49.71 miles) 9/125 μm Fiber type 9/125 μm single-mode...
Page 31
Prepare the transceiver modules yourself as required. H3C recommends that you use H3C SFP transceiver modules for the device. H3C does not guarantee the compatibility of SFP transceiver modules from other vendors with the device. The device reports an alarm when non-H3C SFP transceiver modules are installed.
Copper SFP transceiver module—Category-5 straight-through or crossover twisted pair cable when • the port is operating at 10/100 Mbps and Category-6 twisted pair cable when the port is operating at 1000 Mbps. For the appearance and connection of the interface cables, see "Connecting an Ethernet interface cable"...
NOTE: Use only H3C transceiver modules for the router. Transceiver modules from other vendors might be incompatible with the router. The router reports an alarm when a non-H3C transceiver module is installed. Interface cables Use interface cables for the HIM- 1 6GBP transceiver module as follows: Fiber SFP transceiver module—Fiber that uses an LC connector.
Page 34
Front panel Figure 21 Front panel (1) Captive screw (2) Ejector lever (3) SFP+ port LED (LINK/ACT) (4) SFP+ port LEDs Table 31 SFP+ port LED description Status Description No link is present. Steady green A link is present but no data is being transmitted or received. Flashing green A link is present and data is being transmitted and received.
Item Specification Fiber type 62.5/125 μm multi-mode 9/125 μm single-mode 9/125 μm single-mode Interface cables Use an SFP+ transceiver module and an optical fiber that has an LC connector to connect the SFP+ port on the HIM-2EXP interface module. For the appearance and connection of the interface cables, see "Connecting an optical interface cable."...
Item Specification Interface standards 802.3, 802.3u, 802.3ab Interface type Auto MDI/MDI-X • Ethernet_II Supported frame format • Ethernet_SNAP Transmission distance 100 m (328.08 ft) 10 Mbps Full/half duplex, auto-negotiation Interface speed and duplex 100 Mbps Full/half duplex, auto-negotiation mode 1000 Mbps Full duplex NOTE: The MDI standard is typically used on the Ethernet interface of network adapters;...
Page 37
Front panels Figure 23 Front panel of MIM-8E1(75) (1) DB-68 connector (2) Carrier signal LED (LINK/ACT) (3) Captive screw (4) Loopback/alarm LED (LP/AL) Figure 24 Front panel of MIM-8E1(75)-F The front panel of MIM-8E1(75)-F is similar to that of MIM-8E1(75). LEDs Table 35 LED description Status...
Item Specification Working modes E1, CE1, and FE1 (supported by the MIM-8E1(75)-F only) • Backup Services supported • Terminal access service Interface cables The MIM-8E1(75) or MIM-8E1(75)-F provides eight E1 ports and uses a 75-ohm splitter cable. At one end of this 16-core coaxial cable is a DB-68 connector used to connect to the device, and at the other end are 16 BNC connectors used to connect to the peer devices.
Figure 26 Front panel of MIM-8T1-F The front panel of the MIM-8T1-F is similar to that of the MIM-8T1. Interface specifications Table 37 Interface specifications Item Specification Connector type RJ-45 Number of interfaces • G.703/T1 102 • G.704 • AT&T TR 54016 Interface standard •...
NOTE: The MIM-8T1/MIM-8T1-F does not support ISDN PRI. • For the MIM-8T1, if you use the timeslot binding command on the controller T1 interface, the system • automatically creates the corresponding serial interface, on which you can make configurations. The MIM-8T1-F does not have a controller T1 interface, and a physical interface corresponds to one and only one serial interface, which is automatically created without the need of additional configuration.
Status Description Carrier signals are received. Flashing Data is being transmitted or received. No loopback or alarms occur. The interface is in loopback state. A minimum of one alarm of the type of AIS, LFA, or RAI has LP/AL occurred. •...
Page 42
NOTE: T3 represents the tertiary group rate of the T series in the TDM system, which is 44.736 Mbps. • A T3 channel can be channelized into 28 T1 channels through the demultiplex processes of T23 and • T12, with each T1 channel supporting both the T1 and CT1 operating modes. T23 indicates either T2-to-T3 multiplex or T3-to-T2 demultiplex, and T12 indicates T1-to-T2 multiplex or T2-to-T1 demultiplex.
Item Specification • G.703 • G.704 • G.752 Interface standards • AT&T TR 54014 • AT&T TR 62415 • ANSI T1.107 Interface speed 44.736 Mbps Cable type 75-ohm T3 coaxial cable Working modes T3/CT3 Services supported T3 leased line Interface cables The MIM- 1 CE3 provides two SMB interfaces, with one interface acting as the transmission end (Tx) and the other as the receiving end (Rx).
Page 44
Figure 30 Front panel of MIM-4SAE (1) Serial interface (2) Serial interface LINK LED (3) Captive screw (4) Serial interface ACT LED Figure 31 Front panel of MIM-8SAE (1) Serial interface (7) (2) Serial interface 7 LINK/ACT LED (3) Captive screw (4) Serial interface 3 LINK/ACT LED (5) Serial interface (3) LEDs...
Page 45
Interface specifications Table 45 Interface specifications Item Specification (in synchronous mode) Connector type DB-28 • MIM-2SAE: 2 • MIM-4SAE: 4 Number of interfaces • MIM-8SAE: 8 V.24 V.35, RS-449, X.21, RS-530 Interface standard and working mode DTE, DCE DTE, DCE Minimum baud rate 1200 bps 1200 bps...
The SAP-48GBE is a 10Base-T/100Base-TX/1000Base-T auto-sensing Ethernet service module developed by H3C. The SAP-48GBE provides 48 RJ-45 interfaces, all of which feature Layer 3 routing and high-performance Layer 2 switching. Each interface uses a bi-color LED indicating the running status of the interface.
Page 47
Item Specification • DDR2 SDRAM • 2 GB (default, two 1 GB memories) Memory type and size CAUTION: Use two DDR2 SDRAM with the same size at a time. NVRAM 128 KB • Tested—162 W Max. power consumption • Theoretical—200 W NOTE: The theoretical max power consumption, greater than the tested max power consumption, is the upper power consumption threshold defined for the SAP to prevent power module overloading.
Item Specification 10 Mbps Full/half duplex, auto-negotiation Interface speed and duplex 100 Mbps Full/half duplex, auto-negotiation mode 1000 Mbps Full duplex Interface cables The SAP-48GBE uses a category-5 straight-through or crossover Ethernet cable when operating at 10/100 Mbps, and uses a category-6 cable (recommended) when operating at 1000 Mbps. For the appearance and connection of a SAP-48GBE interface cable, see "Connecting an Ethernet interface cable."...
Page 49
Item Specification • Tested—125 W Max power consumption • Theoretical—150 W NOTE: The theoretical max power consumption, greater than the tested max power consumption, is the upper power consumption threshold defined for the SAP to prevent power module overloading. You must use the theoretical max power consumption, rather than the tested max power consumption, to calculate the total power consumption for managing power modules and determining power module numbers.
SAP-24GBP supports 10/100/1000 Mbps auto-sensing if used together with a transceiver module.) The SAP-24GBP is optional to be separately ordered if needed. Use transceiver modules provided by H3C only. The device might be incompatible with other transceiver modules. Interface cables When working with SFP transceiver modules, the SAP-24GBP must use an optical fiber with LC-type •...
Page 51
Front panel Figure 34 Front panel (1) SFP port (2) System status LED (RUN) (3) SFP status LED (4) Ejector lever (5) Captive screw Specifications Table 52 Specifications Item Specification Flash 4 MB • DDR2 SDRAM • 2 GB (default, two 1 GB memory modules) Memory type and size CAUTION: Use two DDR2 SDRAM modules of the same size at a time.
Page 52
SAP-48GBP supports 10/100/1000 Mbps auto-sensing if used together with a transceiver module.) The SAP-48GBP is optional to be separately ordered if needed. Use transceiver modules provided by H3C only. The device might be incompatible with other transceiver modules and thus displays alarms automatically. Interface cables When working with SFP transceiver modules, the SAP-48GBP must use an optical fiber with LC-type •...
When working with transceiver modules supporting fiber-to-copper conversion, the SAP-48GBP • uses category-5 straight-through or crossover Ethernet cables when operating at 10/100 Mbps, and uses category-6 cable (recommended) when operating at 1000 Mbps. For the appearance and connection of a SAP-48GBP interface cable, see "Connecting an Ethernet interface cable"...
Page 54
LEDs Table 56 LED description Status Description No power input is available or the SAP-4EXP has failed. Slow flashing (1 Hz) The SAP-4EXP is operating correctly. System software image is being loaded or the SAP-4EXP is not operating. (Green) Fast flashing (8 Hz) CAUTION: To avoid hardware damage, do not power off the router, or insert or remove the SAP-4EXP when the software image is being loaded.
SAP-20GE2XP The SAP-20GE2XP provides 16 SFP ports, four combo interfaces, and two SFP+ ports. It provides a bi-color LED for each port to indicate the operating status of the port. It also provides a RUN LED to indicate the operating status of the module. Front panel Figure 36 Front panel (1) SFP ports (GE0 to GE15)
Page 56
LEDs Table 60 LED description Status Description No power input is available or the SAP-20GE2XP has failed. Slow flashing (1 Hz) The SAP-20GE2XP is operating correctly. System software is being loaded or the SAP-20GE2XP is not operating. (green) CAUTION: Fast flashing (8 Hz) To avoid hardware damage, do not power off the router, or insert or remove the SAP-20GE2XP when the software image is being loaded.
Page 57
Item Specification Network Supported synchronization 1588v2.2 protocol Supported Interface standards 802.3, 802.3u, and 802.3ab Short-distance, Medium-distance Super long Long-distanc Long-distance Type multi-mode , single-mode distance e (1310 nm) (1550 nm) (850 nm) (1310 nm) (1550 nm) Transmit power Min. –9.5 dBm –9 dBm –2 dBm –4 dBm...
Page 58
0.65 m (2.13 ft) LSWM2STK 1.2 m (3.94 ft) 10.31 Gbps Used for connecting SFP+ ports LSWM3STK 3 m (9.84 ft) LSTM1STK 5 m (16.40 ft) NOTE: Use transceiver modules provided by H3C only. The router might be incompatible with other transceiver modules.
Interface cables Use the following cables for the SAP-20GE2XP ports: • Fiber port—An SFP/SFP+ transceiver module and a fiber that has an LC connector. Combo copper port operating at 10/100 Mbps—Category-5 straight-through/crossover network • cables. Combo fiber port operating at 1000 Mbps—Category-6 network cables. •...
Page 60
Item Specification • Copper port—Straight-through/crossover autosensing: Combo interfaces 10/100 Mbps, half/full-duplex. 1000 Mbps, full-duplex. • Fiber port—1000 Mbps, full-duplex. Hot swapping Supported. • Tested—132 W. Max power consumption • Theoretical—150 W. LEDs Table 68 LED description Status Description No power input is available or the SAP-28GE has failed. Slow flashing (1 Hz) The SAP-28GE is operating correctly.
Page 61
Interface specifications Table 69 SFP port specifications Item Specification Connector type Transceiver module type Network Supported synchronization 1588v2.2 protocol Supported Interface standards 802.3, 802.3u, and 802.3ab Short-distance, Medium-distance Super long Long-distance Long-distance Type multi-mode , single-mode distance (1310 nm) (1550 nm) (850 nm) (1310 nm) (1550 nm)
Page 62
69. For the transceiver module available for the combo fiber ports, see Table NOTE: Use transceiver modules provided by H3C only. The router might be incompatible with other transceiver modules. Interface cables Use the following cables for the SAP-28GE ports: SFP port—An SFP transceiver module and a fiber that has an LC connector.
Pinout No. Brown Brown Table 73 Crossover cable pinouts Pinout No. Orange/white Green/white Orange Green Green/white Orange/white Blue Blue Blue/white Blue/white Green Orange Brown/white Brown/white Brown Brown NOTE: Strictly follow the pinouts in the above tables when identifying or making the two types of Ethernet cables; otherwise, the communication quality might be affected.
Connecting an optical fiber CAUTION: Never stare into an open fiber Ethernet port, because invisible rays might be emitted from the port. • Cover the dust cover if no optical fiber connector is connected to the copper Ethernet port. • To connect an optical fiber: Insert the SFP/SFP+/XFP transceiver module to the SFP/SFP+/XFP port on the interface module or service module.
Page 67
H3C recommends that you install a special lightning arrester at the input end of its connection cable to obtain better lightning protection when the cable is led outdoors. For more information about lightning arrestor, see the installation guide.
Page 68
Figure 46 Connecting the 4E1/8E1 splitter cable (1) If the 75-ohm 4E1/8E1 splitter cable need be extended, you can connect the BNC connector of the cable to the coaxial cable connector and connect the other end of the coaxial cable connector to the peer device through a 75-ohm E1 trunk cable.
NOTE: The Tx end of the cable must be connected to the Rx end of the peer device, and the Rx end of the cable • to the Tx end of the peer device. The coaxial cable connector and 75-ohm E1 trunk cable are optional accessories to be separately •...
• insertion, which might damage the interface module or even the host. H3C recommends that you install a special lightning arrester at the input end of its connection cable to • obtain better lightning protection when the cable is led outdoors. For more information about lightning arrestor, see the installation guide.
Page 73
Figure 60 RS-530 DCE cable Pos.25 Pos.1 Pos.28 Pos.1 Connecting the cable CAUTION: • Never stare into an open fiber Ethernet port, because invisible rays might be emitted from the port. Cover the dust cover if no optical fiber connector is connected to the fiber Ethernet port. •...
Page 80
Index C H I M S HIMs,1 Compatibility matrixes on Comware V5,70 Compatibility matrixes on Comware V7,71 Interface module and FIP compatibility matrix,72 Connecting a CE3/CT3 interface cable,66 Interface module&SAP and transceiver module compatibility matrix,73 Connecting a serial interface cable,67 Connecting a T1 interface cable,65 Connecting an E1 interface...
Need help?
Do you have a question about the SR6600 and is the answer not in the manual?
Questions and answers