Ip Netstream Export V9-Template Refresh-Rate Time - H3C SR6600 Command Reference Manual

Network management and monitoring command reference
Hide thumbs Also See for SR6600:
Table of Contents

Advertisement

Default command level
3: Manage level
Parameters
packets: Specifies the number of packets that are sent before version 9 templates are sent to the
NetStream server for an update. The value is in the range of 1 to 600.
Usage guidelines
Version 9 is template-based and supports user-defined formats, so the NetStream-enabled device needs
to send the new template to the NetStream server for an update. If the version 9 format is changed on the
NetStream-enabled device and not updated on the NetStream server, the server is unable to associate
the received statistics with its proper fields. To avoid such situation, configure the refresh frequency for
version 9 templates so that the NetStream server can refresh them on time.
The refresh frequency and interval can both be configured, and the template is resent when either of the
condition is reached.
Examples
# Configure the device to wait until 100 packets are sent before sending NetStream version 9 templates
again to the NetStream server.
<Sysname> system-view
[Sysname] ip netstream export v9-template refresh-rate packet 100
Related commands

ip netstream export v9-template refresh-rate time

ip netstream export v9-template refresh-rate time
Use ip netstream export v9-template refresh-rate time to configure the refresh interval for NetStream
version 9 templates so that the templates are sent after the specified time period.
Use undo ip netstream export version to restore the default.
Syntax
ip netstream export v9-template refresh-rate time minutes
undo ip netstream export v9-template refresh-rate time
Default
Version 9 templates are resent every 30 minutes.
Views
System view
Default command level
3: Manage level
Parameters
minutes: Specifies the refresh interval in minutes that the device waits after NetStream version 9 templates
are sent to the NetStream server. The value is in the range of 1 to 3600.
Usage guidelines
Version 9 is template-based and supports user-defined formats, so the NetStream-enabled device needs
to send the new template to the NetStream server for an update. If the version 9 format is changed on the
176