If The Software Installation Fails; For A Vnx Boot Array; For A Symmetrix Boot Array - EMC VNX VG2 Setup Manual

Table of Contents

Advertisement

If the software installation fails

For a VNX boot
array
For a Symmetrix
boot array
If the NAS software installation fails, the system should display one or more error
messages with resolution instructions. Start by correcting any problems indicated by
error messages.
Chapter 10, "Complete Phase 3 Installation,"
Note:
Proactive Health Check (PAHC) feature that uses the nas_checkup command.
Reboot the Control Station if the installation fails before you see this prompt:
Continue with EMC NAS Installation [yes or no]
The setup script will restart. You need not delete or re-create the control LUNs or
hypervolumes.
If the installation fails after the following prompt, complete the following steps for the
array type that you are using:
Continue with EMC NAS Installation [yes or no]
If the installation fails:
1. Use Navisphere Manager or the Navisphere CLI to unbind the control LUNs and
remove the empty RAID group.
2. If manually configuring the VNX, recreate the RAID group and control LUNs.
Refer to
"Create control LUNs on VNX array" on page
3. Reinstall the NAS and Control Station software.
If the installation fails:
1. Have the EMC Symmetrix administrator delete and re-create the system
hypervolumes.
2. Reinstall the NAS and Control Station software.
EMC CONFIDENTIAL
NAS Install Options
provides more information about the
, .
, .
237.

If the software installation fails

229

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VNX VG2 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Vnx vg8

Table of Contents