Connecting A Vnx5100 Array - EMC VNX VG2 Setup Manual

Table of Contents

Advertisement

Connecting a
VNX5100 array
Figure 67
If all of the SAN ports on the array are already connected to the fabric, you need not
change these connections. If the array has two available ports on each SP, the
recommended practice is to cable these ports to the switches and dedicate them to the
VNX gateway system.
If you are using two switches to connect a VNX5100 array, connect the cables as
shown in the example in
Figure
Switch B
SP B
4
2
VNX5100 connected to two switches for high availability (example)
The array SAN ports 2 and 3 are used in this example, but you can use any two ports
on each SP:
1. Connect SP A slot 0, port 2 to switch A.
2. Connect SP B slot 0, port 2 to switch A.
3. Connect SP A slot 0, port 3 to switch B.
4. Connect SP B slot 0, port 3 to switch B.
5. Record the SP ports you connected to the switch ports by using the
cabling worksheet" on page
Connect Cables for a Fabric-connected VG8
65.
SP A
3
3
2
2
1
1
0
0
3
273.
Step 2: Array Fibre Channel cables
EMC CONFIDENTIAL
Switch A
1
CNS-000892
"FC/FCoE
103

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VNX VG2 and is the answer not in the manual?

This manual is also suitable for:

Vnx vg8