e. Enter the domain and hostname for the Control Station. Optionally, enter
secondary and tertiary nameserver IP addresses. Tab to Ok and press Enter.
Figure 120
Example of Configure Network window
11. After setting up the enclosures, the system reports the number of Data Movers
detected. If the system reports the correct number of Data Movers, enter yes to
confirm, and go to
12. If the system does not report the correct number of Data Movers, enter no.
The system returns to the command prompt. Do the following:
a. Verify that the network cables from the Control Station to the Data Movers are
correctly connected and fully seated.
b. Enter the reboot command to try discovering the Data Movers again.
c. If the system still reports the wrong number of Data Movers, contact EMC
Customer Service.
The system displays the following message:
Checking for existing system RG/LUN
13. The Celerra Install/Upgrades dialog box appears. If the system prompts you to
choose the system configuration
System configuration settings
Figure 121
A confirmation prompt appears.
step 13
.
.
(Figure
121), select Gateway and press Enter.
Express Install for File OE release 7.0 or lower
EMC CONFIDENTIAL
NAS Install Options
209