Connect Cables for a Direct-connected VG8
Step 4: Private LAN cables
Figure 84
120
EMC VNX VG2/VG8 Gateway Configuration Setup Guide
The private (internal) LAN cables connect the Control Station to the blades through
the blade enclosure's management modules. These cables and switches make up a
private network that does not connect to any external network.
The blade enclosure has two management modules, which are redundant. If module
A fails, module B assumes control of the private network. The Control Stations
communicate to the blades through the management modules.
The VG8 system has an internal network formed by daisy-chaining the management
modules attached to each enclosure. The Control Stations communicate to all blades
through the management modules on both sides of the enclosures.
Figure 84
shows the VG8 management module with the private LAN ports 0, 1, and
2.
Management
module B
Management module for blade enclosure
Verify the cables are installed correctly and the connectors are fully seated. Refer to
Figure 85 on page 121
for cabling the Control Station to blade enclosure 0 and
Figure 86 on page 122
for cabling (daisy-chaining) the blade enclosures:
1. Verify that an RJ-45 Ethernet cable connects from port 1 on management module
A in blade enclosure 0 (blades 2 and 3) to the port labeled A on CS 0. This is cable
#1 in
Figure 85 on page
2. Verify that an RJ-45 Ethernet cable connects from port 1 on management
module B in blade enclosure 0 (blades 2 and 3) to the port labeled B on CS 0. This
is cable #2 in
Figure 85 on page
3. If required, verify that an RJ-45 Ethernet cable connects from port 2 on
management module A in blade enclosure 0 (blades 2 and 3) to the port labeled A
on CS 1. This is cable #3 in
Port 2
Port 0
Port 1
Management
module A
121.
121.
Figure 85 on page
121.
CNS-001679