Command Sets /Drivers; Mechanical Characteristics - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

ReFlex Power™
Output Relays
Isolation relays are optionally provided on the main and auxiliary outputs.
C
4.3.7
OMMAND
Command Description
SCPI Standard 1999 command language, through Controller Module
Response Description
SCPI Standard 1999 command language, through Controller Module
Command Execution Time
100ms from command request
M
4.3.8
ECHANICAL
Dimensions
4.2 inch wide, 6.75 inch high, and 15 inch deep
Weight
11.4 pound, maximum
Cooling Provisions
Operation at maximum limits of output power, ambient temperature, and
altitude requires adequate airflow through module: 40 CFM
Color
Black, color number 27038 per FED-STD-595
Acoustic Noise
The speed of the integral fans is linearly variable, as a function of internal
heatsink temperature rise, to minimize acoustic noise and extend the fan life.
The speed varies from nominally 50% of full-speed to full-speed as the
heatsink temperature varies with ambient temperature and power dissipation
resulting from the output load.
M380056-01 Rev L