Module Installation - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

Mainframe
M
2.4.4
ODULE
CAUTION
Modules and the Mainframe contain ESD sensitive circuitry.
Follow appropriate handling and grounding procedures to prevent
damage to a module or Mainframe. Modules and Mainframe
should be handled by the enclosure, with care to protect the
connectors from ESD discharges.
CAUTION
Input power must be disconnected to the Mainframe before
a module is inserted or extracted. Inserting or extracting a
module with power installed (hot-swapping) could result in
damage to the module or Mainframe. Prior to turning power
on, ensure that front panel captive thumbscrews are
tightened.
Modules are installed into the Mainframe from the front of the chassis. Refer to
Figure 2-3 for the orientation of a module and Mainframe during installation.
1. Ensure that the AC/DC input power is disconnected before
2. Insert the module into the mainframe, rear panel first, aligning the
3. Gently slide the module completely into the mainframe until the
4. Fully seat the module until the front panel inner surface is snug
5. Secure the module(s) to the Mainframe at the top and bottom of
6. Install a filler panel over any empty slot, and secure in place at the
2-10
I
NSTALLATION
installing or removing any module(s).
module guide rails the top and bottom Mainframe guides.
guide pins of the module rear connector engage the mating
backplane connector.
against the mainframe chassis.
each front panel by turning the captive thumbscrews clockwise
using a flat head screwdriver to a maximum torque of 20 in-lb.
top and bottom by turning the captive thumbscrews clockwise
using a flat head screwdriver to a maximum torque of 20 in-lb.
ReFlex Power™
M380056-01 Rev L