DC Power Supplies
C
URRENT
RFP-D1016-021-XXXX, RFP-D1065-5A1-XXXX:
RFP-D2033-030-XXXX, RFP-D2050-020-XXXX, RFP-D2050-025-XXXX,
RFP-D2120-8A3-XXXX, RFP-D2450-2A3-XXXX:
C
URRENT
0.1% of full-scale for 100% load change
M
6.3.3
EASUREMENT
V
OLTAGE
0.1% of set point plus 0.1% of full scale, at 25 °C, +/- 5 °C
V
OLTAGE
RFP-D1016-021-XXXX:
RFP-D1065-5A1-XXXX:
RFP-D2033-030-XXXX:
RFP-D2050-020-XXXX:
RFP-D2050-025-XXXX:
RFP-D2120-8A3-XXXX:
RFP-D2450-2A3-XXXX:
C
URRENT
0.1% of full-scale plus 0.2% of set-point, at 25 °C, +/- 5 °C
C
URRENT
RFP-D1016-021-XXXX:
RFP-D1065-5A1-XXXX:
RFP-D2033-030-XXXX:
RFP-D2050-020-XXXX:
RFP-D2050-025-XXXX:
RFP-D2120-8A3-XXXX:
RFP-D2450-2A3-XXXX:
S
6.3.4
UPERVISORY
O
VERVOLTAGE
The OVP operation is user -selectable to be programmable or tracking. The
default mode of operation is programmable OVP.
6-10
L
R
INE
EGULATION
0.05% of full-scale for 10% line change
0.1% of full-scale for 10% line change
L
R
OAD
EGULATION
A
CCURACY
R
ESOLUTION
A
CCURACY
R
ESOLUTION
C
HARACTERISTICS
(OVP)
Programmable operation: The OVP threshold is programmable
from 5 to 110% of full-scale output voltage.
Tracking operation: The OVP threshold is automatically
adjusted to 110% above the programmed value of the output
0.47mV
1.9mV
2mV
3mV
3mV
7mV
28mV
1.28mA
0.32mA
1.9mA
1.3mA
1.6mA
0.6mA
0.14mA