Connectors J1 and J2 contain high-speed digital signals that require controlled cable
impedances; connectors J3 and J4 contain noise-sensitive analog signals. Therefore, to
maintain signal integrity, cables must conform to construction requirements of AMETEK cable
assembly 53800054.
Connector
J1
J2
J3
J4
J5
W
2.4.10
IRE
Input/output wiring must have a current carrying capacity compatible with the
current rating of the ReFlex Power™ system. The maximum current rating of a
wire is dependent on the materials used in its construction, and is primarily
limited by the insulation. The current must be limited so that the temperature rise
of the wire does not result in an operating temperature that exceeds the rating of
the wire.
W
C
IRE
URRENT
Table 2-11 shows maximum current ratings, based on a cable of three
conductors, that will produce an approximate 30ºC temperature rise above
ambient. When wiring must operate in areas with an elevated ambient
temperature or bundled with other wiring, heavier gauges or higher
temperature-rated wiring should be used.
Although wire with higher temperature rated insulation will allow operation at
higher currents, the total voltage drop would also be increased for a given
wire gauge. For applications where voltage characteristics, such as
regulation, are important, it may be necessary to size the wire based on total
voltage drop instead of temperature rise.
M380056-01 Rev L
Mainframe J1, J2, J3, J4, and J5 Connector Wire Size/Length
Maximum Wire
Pin
Gauge, AWG
All
All
All
All
All
S
ELECTION
C
APACITY
Maximum Wire Length, ft
30, total aggregate for all Mainframe
22
interconnecting cables
30, total aggregate for all Mainframe
22
interconnecting cables
30, total aggregate for all Mainframe
20
interconnecting cables
30, total aggregate for all Mainframe
20
interconnecting cables
Dependent on input source voltage
and permitted line drop at 24A per
10
line maximum current for fully
populated Mainframe
Mainframe
2-27