Voltage Programming Range
0 to 102% of full scale
Voltage Digital Programming Accuracy
(0.1% + 0.2%/kHz) of full scale, at 25 °C, +/- 5 °C; from .25% to 102% of
voltage range
Voltage Digital Programming Resolution
0-140VAC range: 20mV; 0-280VAC range: 40mV
Voltage Temperature Drift
0.05% of full scale/degree °C, maximum
Voltage Stability
0.1% of full scale per week at constant line, load, and temperature
0.4% of full scale per 1000 hours at constant line, load, and temperature
Voltage Load Regulation
RMS load regulation is 0.1% of full scale for 100% resistive load change
Voltage Line Regulation
RMS line regulation is 0.1% of full scale for line variation of 10% of nominal
Voltage Load Transient
With a load change from no load to full load, or vice versa, the maximum
undershoot or overshoot shall be as follows:
0.5% of full scale voltage at 60 Hz
1% of full scale voltage at 400 Hz
5% of full scale voltage at 1200 Hz
10% of full scale voltage at 5000 Hz
And will have a maximum recovery time of 100ms to within .5% of full scale
voltage; tested at nominal output voltage and after 1 mSec, to exclude the
initial output filter spike.