General Characteristics; Input /Output Connections - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

ReFlex Power™
G
5.3.4
ENERAL
I
V
NPUT
103.5-253VAC with AC input; 270VDC, nominal; 210VDC, minimum to 300VDC,
maximum; 314VDC, maximum for 2s; 364.5VDC, maximum for 450ms
I
C
NPUT
URRENT
Power factor corrected single-phase AC input; unipolar DC input; sinusoidal current
with AC input; continuous DC current with DC input.
At 103.5 VAC input and full power output, the input current is 2.75 A maximum.
P
F
OWER
ACTOR
> 0.95 at full output load, >0.75 at 20% output load, decreasing to 0.3 at no load
E
FFICIENCY
60% minimum
F
P
RONT
ANEL
OUTPUT (LED, green): output enabled and isolation relay closed
POWER (LED, green): input AC/DC power applied to module
FAULT (LED, red): internal abnormal operating condition detected; output disabled
and isolation relay opened
BUS (LED, green): internal bus communication established
I
/O
5.3.5
NPUT
O
I
UTPUT
SOLATION
Each voltage output is isolated from the input line, the other output voltages, and the
module case by at least 1 Meg Ohm.
O
R
UTPUT
Each output is provided with an isolation relay.
M380056-01 Rev L
C
HARACTERISTICS
R
OLTAGE
ANGE
I
NDICATORS
C
UTPUT
ONNECTIONS
ELAYS
Fixed Power DC Power Supply
5-7

Advertisement

Table of Contents
loading