Table 5 5. Calibration Power Connector - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

ReFlex Power™
Table 5-5. Calibration Power Connector
Pin
10
11
12
13
14
15
16
17
A1
A2
A3
A4
Either enable the FPDC module if there is an available means, or create
another special connector to insert in the control jack on the FPDC module, see
below.
FPDC C
ONTROL
Mating connector: 9 pin D_SUB:
Positronic Subminiature-D SD Series, SD9M1000Z, crimp male contacts
Wire size recommended: 22 AWG
With a short wire connect pins 1 to pin 6. With this connector inserted, the
FPDC outputs will be on.
M380056-01 Rev L
Signal
1
+15 V
2
+15 V RTN
3
-15 V
4
-15 V RTN
5
6
7
8
9
CHAS GND
+ 5 V
+ 5 V RTN
- 5 V
- 5 V RTN
C
:
ONNECTOR
Connect To
DMM +
DMM -
DMM +
DMM -
A1
A3
10
12
NC
7
16
8
17
A2
A4
11
13
5 & DMM+
14 & DMM -
6 & DMM -
15 & DMM +
Fixed Power DC Power Supply
Type
Stub
Stub
Stub
Stub
Stub
Stub
Stub
Stub
5-29

Advertisement

Table of Contents
loading

Table of Contents