Ametek Elgar ReFlex Power Operation Manual page 169

Table of Contents

Advertisement

AC Power Supplies
26. Perform the voltage calibration:
27. Send the system error query command to make sure calibration was successful:
28. If there is no error returned at the system error query command then save the
calibration data
29. Reset the unit
4-84
CAL<n>:OUTP:FREQ:CURR7 <value-7>
CAL<n>:OUTP:FREQ:CALC
SYST:ERR?
CAL<n>:UNLOCK "6867"
CAL<n>:STORE
CAL<n>:LOCK
*RST<n>
ReFlex Power™
M380056-01 Rev L

Advertisement