The following procedure calibrates offset of the voltage ADC for the voltage
range high.
1. Ensure that no load is connected to the output.
2. Issue clear and reset commands:
3. Set the voltage range of the power supply to high
4. Perform the voltage ADC offset calibration
5. Send the system error query command to make sure calibration was successful.
6. If there is no error returned at the system error query command then save the
calibration result with the following command
7. Optional Commands:
8. Reset the unit
M380056-01 Rev L
ADC O
FFSET
*CLS
*RST<n>
SOUR<n>:VOLT:RANGE 1
CAL<n>:MEAS:VADC:OFFSET:CALC
SYST:ERR?
CAL<n>:UNLOCK "6867"
CAL<n>:STORE
CAL<n>:LOCK
To query the voltage ADC offset: CAL<n>:MEAS:VADC:OFFSET ?