NPUT
The RFPC module will operate from a wide variety of AC and DC input power
sources, as distributed through the Mainframe. Although the Mainframe could be
connected to either single-phase or three-phase AC power, the module has
single-phase inputs. It is connected to the source, through the Mainframe, either
phase to neutral, or line-to-line, depending on the available source voltage. The
power source voltage must be within the range of 103.5-253VAC at 47-63Hz and
400Hz. The input voltage ranges are continuous, and do not require any manual
setup.
CAUTION
Exceeding the maximum rated AC/DC input voltage could result in
damage to the module.
See Mainframe section for detailed input power requirements, including input
power allocation.
AC/DC I
3.4.6
Over-current protection must be provided externally, within the system
installation, for the AC/DC input of the Mainframe. Refer to the Mainframe section
of this manual for recommendations.
3-12
Figure 3-3. Module Installation
P
R
OWER
EQUIREMENTS
O
NPUT
VERCURRENT
P
ROTECTION