Figure 5 6. Fpdc Dc Output Connector, Front Panel View, And Wiring Diagram - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

ReFlex Power™
DC O
UTPUTS
The FPDC Output connector, J2, provides terminations for the 4 DC voltages and
associated remote sense connections to the load(s).
DC Output Connector
Connector: Positronic Industries P/N CBC21WA4M1000Z,
Pins 1 – 17: Positronic Industries P/N MC6020D, AMETEK P/N 856-214-04
Pins A1 – A4: Positronic Industries P/N MC4012D, AMETEK P/N 856-745-52
Figure 5-6. FPDC DC Output Connector, Front Panel View, and Wiring Diagram
M380056-01 Rev L
AMETEK P/N 856-214-04 (crimp signal contacts)
Wire size: Maximum gauge 20 AWG (recommended)
Length: Maximum 10 meters
Wire size: Maximum gauge 12 AWG (recommended
Length: Maximum 10 meters
Backshell: Positronic Industries P/N D37000Z00, AMETEK P/N
856-247-39
DC Output
T/P
+5V
A1
+5V RTN
A2
T/P
+5 S+
5
+5 S RTN
14
T/P
-5V
A3
-5V RTN
A4
T/P
-5 S-
6
-5 S RTN
15
T/P
+15V
1
2
+15V RTN
T/P
+15V
10
+15V RTN
11
T/P
+15 S+
7
+15 S RTN
16
T/P
-15V
3
-15V RTN
4
T/P
-15V
12
-15V RTN
13
T/P
-15 S-
8
-15 S RTN
17
CHAS GND
9
Fixed Power DC Power Supply
T/P
T/P
T/P
T/P
T/P
T/P
T/P
T/P
T/P
T/P
T/P = Twisted Pair; N/U = Not Used
+5V
Load
-5V
Load
+15V
Load
-15V
Load
5-19