Environmental Characteristics - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

ReFlex Power™
Hold-Up Time
10ms, with dropout of AC input at full output power except
RFP-D2050-025-xxxx: 8
Aggregate Output Power
Depends on module complement and input voltage: With AC input
voltage ≥ 200VAC or DC input, 6kW maximum; with AC input voltage
< 200VAC, 3.6kW maximum
E
1.3.5
NVIRONMENTAL
The ReFlex Power™ system has been ruggedized to MIL-PRF 28800F
requirements for Class 3. It is capable of operating in military
environments,
environmental conditions of temperature, altitude, shock/vibration, and
input power.
O
PERATING
Temperature:
Altitude:
Humidity:
Shock:
Vibration:
Operation Without Fully Populated Mainframe:
M380056-01 Rev L
ms, with dropout of AC input at full output power
C
HARACTERISTICS
with
enhanced
E
C
NVIRONMENTAL
Standard: 0 to 50 °C
Extended Range Option: -10 to 55 °C
Standard: 0 to 6,500 feet
Extended Range Option:
Low-Power DC, High-Power DC, Fixed-Power DC, AC Power, and
Low-Power Load assets: 0 to 15,000 feet
High-Power Load asset: 0 to 15,000 feet, with linear temperature
derating from 55°C at 6,500 feet to 40°C at 15,000 feet, or with linear
power derating from 750W at 6,500 feet to 600W at 15,000 feet
95% non-condensing
Class 3 MIL-PRF-28800F
Class 3 MIL-PRF-28800F
If Mainframe is not fully populated with modules, filler panels must be
installed in empty slots to maintain proper airflow and structural
integrity.
capabilities
to
ONDITIONS
System Overview
withstand
harsh
1-11