Ametek Elgar ReFlex Power Operation Manual page 289

Table of Contents

Advertisement

Active Loads
I
7.4.3
NSTALLATION
CAUTION
The module contains ESD sensitive circuitry. Follow appropriate handling
and grounding procedures to prevent damage to the module. The module
should be handled by the enclosure, with care to protect the connectors
from ESD discharges.
CAUTION
Input power must be disconnected to the Mainframe before a module is
inserted or extracted. Inserting or extracting a module with power
installed (hot-swapping) could result in damage to the module or
Mainframe. Prior to turning power on, ensure that front panel captive
fasteners are tightened
Modules are installed into the Mainframe from the front of the chassis. Refer to
Figure 7-4 for a view showing the orientation of a module and Mainframe during
installation.
1. Ensure that the Mainframe AC/DC input power is disconnected before
installing or removing any module(s).
2. Insert the module into the Mainframe, aligning the guide rails at the rear of
the module with the top and bottom Mainframe guides.
3. Gently slide the module completely into the Mainframe until the guide pins
of the module rear connector engage the mating backplane connector.
4. Fully seat the module until the front panel inner surface is snug against the
Mainframe chassis.
5. Secure the module(s) to the Mainframe at the top and bottom of each front
panel by turning the captive thumb screws clockwise using a flat blade
screwdriver to a maximum torque of 20 in-lb.
6. Install a filler panel over any empty slot, and secure in place at the top and
bottom by turning the captive thumb screws clockwise using a flat blade
screwdriver to a maximum torque of 20 in-lb.
7-14
.
ReFlex Power™
M380056-01 Rev L

Advertisement

Table of Contents
loading

Table of Contents