Ametek Elgar ReFlex Power Operation Manual page 239

Table of Contents

Advertisement

DC Power Supplies
O
PTIONAL
AMETEK P/N 5380508-01, 9-pin Loop-back Connector Assembly. Includes a
jumper wire between Pins 1 and 6 to enable the module outputs.
AMETEK P/N 5380443-01, Power Module, 9ft. Unterminated Interface Cable
Assembly. Use when interfacing to an external system.
AMETEK P/N 5380443-03, Power Module, Right Angle, 9ft. Unterminated
Interface Cable Assembly. Use when interfacing to an external system.
DC O
UTPUT
The DC OUTPUT connector provides terminations for the output and remote
sense connections to the load.
RFP-D1016-021-XXXX DC Output Connector
Connector: Positronic Industries P/N CBD13W6M2000Z, AMETEK P/N 856-214-07
Pin: Positronic Industries P/N MC4010D, AMETEK P/N 856-745-51
Backshell: Positronic Industries P/N D3T000Z00D37000Z00, AMETEK P/N 856-247-39
Wire size: Refer to table for recommended wire gauge/length
Figure 6-11. RFP-D1016-021-XXXX DC Output Connector, Front Panel View and Wiring Diagram
6-36
I
C
NTERFACE
ONNECTOR
C
:
ONNECTOR
DC Output
Out
Out_Rtn
Out
Out_Rtn
Sense
Sense_Rtn
Chas Gnd
N/U
N/U
N/U
N/U
A
CCESSORIES
T/P
A1
A2
T/P
A3
A4
T/P
1
5
4
2-3
6-7
A5
T/P = Twisted Pair; N/U = Not Used
A6
ReFlex Power™
T/P
T/P
Load
T/P
M380056-01 Rev L