ReFlex Power™
I
3.4.4
NSTALLATION
Modules are installed into the Mainframe from the front of the chassis. Refer to
Figure 3-3 for the orientation of a module and Mainframe during installation.
1. Ensure that the AC/DC input power is disconnected before
2. Insert the module into the mainframe, rear panel first, aligning the
3. Gently slide the module completely into the mainframe until the
4. Fully seat the module until the front panel inner surface is snug
5. Secure the module(s) to the Mainframe at the top and bottom of
6. Install a filler panel over any empty slot, and secure in place at the
M380056-01 Rev L
CAUTION
Inadequate airflow and excessive ambient air temperature
could result in overheating and thermal shutdown.
CAUTION
The module contains ESD sensitive circuitry. Follow appropriate
handling and grounding procedures to prevent damage to the
module. The module should be handled by the enclosure, with
care to protect the connectors from ESD discharges.
CAUTION
Input power must be disconnected from the Mainframe before a
module is inserted or extracted. Inserting or extracting a module
with power installed (hot-swapping) could result in damage to the
module or Mainframe. Prior to turning power on, ensure that front
panel captive fasteners are tightened.
installing or removing any module(s).
module guide rails the top and bottom Mainframe guides.
guide pins of the module rear connector engage the mating
backplane connector.
against the mainframe chassis.
each front panel by turning the captive thumb screws clockwise
with a flat head screwdriver to a maximum torque of 20 in-lb.
top and bottom by turning the captive thumb screws clockwise
with a flat head screwdriver to a maximum torque of 20 in-lb.