ReFlex Power™
HPAL R
7.6.15
The following procedure calibrates the resistance for voltage gain 4 and
current range high. Make sure that the shunt and the DC voltmeter are
connected between the positive and negative leads of the active load.
Connect the sense positive-to-positive lead and sense negative-to-negative
lead. Also connect the shunt and the DC current meter between the active
load and DC power supply.
This procedure requires maximum voltage 50.0 V and maximum current 2.0
Amps.
1. Set the DC input voltage to 50 Volts
2. Turn the active load on:
3. Set the conductance count to 0x7FFF:
4. After DC voltage stabilizes, enter the voltage:
5. After DC current stabilizes, enter the current:
6. Set the conductance count to 0x3C3C:
7. After DC voltage stabilizes, enter the voltage:
M380056-01 Rev L
C
ESISTANCE
ALIBRATION
INP<n>:STATE 1
CAL<n>:INP:COND:COUNTS 0x7FFF
CAL<n>:INP:VOLT 1 <value-1>
CAL<n>:INP:CURR 1 <value-1>
CAL<n>:INP:COND:COUNTS 0x3C3C
– P
III
V
ART
OF
Active Loads
7-47