Ametek Elgar ReFlex Power Operation Manual page 232

Table of Contents

Advertisement

ReFlex Power™
RFP-D2033-030-XXXX, I
External isolated digital and analog control interface.
Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09
Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10
Wire size: Maximum gauge 20 AWG (recommended)
RFP-D2033-030-XXXX I
Figure 6-7. RFP-D2033-030-XXXX Interface Connector, Front Panel View, and Wiring Diagram
Table 6-4. RFP-D2033-030-XXXX Interface Connector Pinout
PIN
NAME
1
1
ENA
6
ENA-RTN
2
TRIG-OUT
7
TRIG-OUT-RTN Output: return for TRIG-OUT; connected to Pin-6/8
3
TRIG-IN
8
TRIG-IN-RTN
4
RESERVED
9
RESERVED
5
CHAS-GND
1
Enable signal is internally pulled up to +5 V with a 10 K resistor. To enable the module, the signal is
pulled low (<= 0.5 V) with respect to the ENA RTN signal; this may also be accomplished by shorting Pin
1 to Pin 6.
M380056-01 Rev L
NTERFACE
Crimp contacts: Positronic Industries P/N MC7520D (initially supplied with
connector)
Maximum length 10 meters (can be extended subject to environment,
cable type, and interface circuits).
NTERFACE
Input: module output enable
1
Input: return for ENA signal; connected to Pin-7/8
Output: trigger output signal
Input: trigger input signal
Input: return for TRIG-IN; connected to Pin-6/7
Shield ground
C
:
ONNECTOR
P
INOUT
FUNCTION
DC Power Supplies
SIGNAL LEVEL
TTL logic level
Signal common
TTL logic level
Signal common
TTL logic level
Signal common
Chassis ground
6-29