Accessories List; Ontrols And Ndicators - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

ReFlex Power™
A
4.2.2
CCESSORIES
The ReFlex Power™ AC power supply modules include the following standard
accessories:
C
4.2.3
ONTROLS AND
The AC power supply module operates within the ReFlex Power™ system as
part of an automated test system, so there are no user manual controls. They
rely on the Mainframe and Controller module for control, status and data
communications, and for input/output connections to the user application. All
output load connections and discrete control interface to the user application are
accessible on the front panel of the modules. Also, the front panel has indicators
for annunciation of the operational state. Input power is routed from the
Mainframe through a backplane distribution.
Figure 4-1 shows a front view of the 875 VA ACPS module. Figure 4-2 shows a
typical rear view of the modules with the backplane connector interface for input
power, discrete digital control signals, analog control signals, and data
communications.
M380056-01 Rev L
User programmable supervisories for current and voltage
ACPS IVI drivers
2 models with Output Frequency Range 45 to 1200 Hz or 45 to 5000
Hz
Auxiliary Output, 22.6 % of Main 140 VAC output, 61VA (low range,
350-1000 Hz), 2A maximum
Two ranges on output, 0-140VAC, and 0-280 VAC
Direct-Coupled output
Measurement capabilities of: V
(versions 2.0 and 3.0) and Active Power, Apparent Power, Reactive
Power, Power Factor, Crest Factor (version 3.0 only).
+/- 30 A
, inrush current.
pk
L
IST
Operation Manual, P/N M380056-01 (this manual)
Programming Manual, P/N M380056-03
Quick Reference Guide, P/N M380056-04
I
NDICATORS
, I
, Frequency, Phase, I
RMS
RMS
AC Power Supplies
pk
4-3

Advertisement

Table of Contents
loading

Table of Contents