Recommended Calibration Equipment; Calibration Setup - Ametek Elgar ReFlex Power Operation Manual

Table of Contents

Advertisement

DC Power Supplies

RECOMMENDED CALIBRATION EQUIPMENT

6.6.2
The recommended calibration equipment is listed in Table 5-14. Equivalent
substitutes are acceptable provided that their accuracy is at least four times
better than the accuracy of the parameter specification that is being calibrated. If
less accurate equipment is utilized, measurement uncertainty may be introduced
that would compromise the validity of the calibration.
Table 6-15. Recommended Calibration Equipment
INSTRUMENT
DC Voltmeter
Current Shunt

CALIBRATION SETUP

6.6.3
Calibration must be performed under controlled environmental conditions. The
ambient temperature must be between 20 to 30 °C. Also, the humidity must be
less than 80%. Allow the unit to warm up for 30 minutes at no load prior to
performing the calibration. Refer to Figure 6-23 for a diagram of the test
instrumentation setup.
6-66
REQUIREMENTS
Resolution: 6 1/2 digits
RFP-D1016-021-XXXX, RFP-D2033-030-XXXX, RFP-
D2050-020-XXXX, and RFP-D2050-025-XXXX:
10mΩ, ±0.04%, (100A)
RFP-D1065-5A1-XXXX, RFP-D2120-8A3-XXXX, and
RFP-D2450-2A3-XXXX:
50mΩ, ±0.04%, (15A)
(+)
Output
(-)
Power
Supply
Module
(+)
Remote Sense
(-)
DVM
Closed for
current
calibration
ReFlex Power™
RECOMMENDED
MODEL
Agilent 34401A
Guildline 9230-100
Guildline 9230-15
Current
Shunt
M380056-01 Rev L

Advertisement

Table of Contents
loading

Table of Contents