ReFlex Power™
7. Send the calibration command to calculate the gain and offset of the
8. Send the system error query command to make sure calibration was
9. If there is no error returned at the system error query command then
10. Reset the unit
M380056-01 Rev L
low range current calibration
CAL<n>:INP:CURR:CALC
successful.
SYST:ERR?
save the calibration result with the following command
CAL<n>:UNLOCK "6867"
CAL<n>:STORE
CAL<n>:LOCK
*RST<n>
Active Loads
7-61