Jogging Operation Function (Jg) - Omron RX2 Series User Manual

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

 Parameter
Item
Selecting the input ter-
minal
Retry wait time before
motor restart
Restart frequency
threshold
8-4-3

Jogging Operation Function (JG)

This function allows you to fine-tune the position where a motor stops.
The jogging operation starts when frequency commands for the operation is set to [AG-20] the jogging
frequency and the [JG] terminal is turned ON.
Input signal
[JG]
Input signal
[FW]
Input signal
[RV]
Output
frequency
Precautions for Correct Use
• The jogging operation is likely to cause a trip as the frequency command is outputted instan-
taneously without acceleration time. Adjust the setting value for the jogging frequency
[AG-20] to prevent the inverter trip.
• For the jogging operation, set the [AA111] operation command selection to 00, turn on the
029[JG] terminal and then put the [FW]/[RV] terminal. The operation is not allowed with the
[JG] terminal alone.
• When [AG-21] = 00, 03 for the free-running at the time of the stop, the operation settings for
free-running is required.
• When [AG-21] = 02, 05 for the DC-braking at the time of the stop, the settings for the
DC-braking function is required. Refer to 7-6 Stop Conditions on page 7-82 respectively.
High-function General-purpose Inverter RX2 Series User's Manual
Parameter
Data
[CA-01] to
[CA-11]
[bb-26]
0.3 to 100.0(s)
0.00 to
[bb-42]
590.00(Hz)
[AG-20]
Description
035
Used for the commercial switching [CS].
Set the waiting time after an operation com-
mand.
Starting at 0 Hz when the detected value is
equal to or less than the set value.
8 Applied Settings
Default
data
-
3
0.00
8 - 83