8 Applied Settings
Code
PID1 feedback data monitor
db-44
db-50
PID1 output monitor
db-51
PID1 deviation monitor
db-52
PID1 deviation 1 monitor
db-53
PID1 deviation 2 monitor
db-54
PID1 deviation 3 monitor
db-55
PID2 output monitor
db-56
PID2 deviation monitor
db-57
PID3 output monitor
db-58
PID3 deviation monitor
db-59
PID4 output monitor
db-60
PID4 deviation monitor
db-64
PID feedforward monitor
dC-15
Cooling fin temperature monitor -20.0 to 200.0(°C)
*1. Data range varies depending on the data from [AH-04] to [AH-06].
*2. Data range varies depending on the data from [AJ-04] to [AJ-06].
*3. Data range varies depending on the data from [AJ-24] to [AJ-26].
*4. Data range varies depending on the data from [AJ-44] to [AJ-46].
Code
FA-01
Main speed command monitor
Auxiliary speed command mon-
FA-02
itor
FA-15
Torque command monitor
FA-16
Torque bias command monitor
FA-30
PID1 target value 1
FA-32
PID1 target value 2
FA-34
PID1 target value 3
FA-36
PID2 target value
FA-38
PID3 target value
FA-40
PID4 target value
*1. To calculate the motor rated torque (100%), use the following formula.
Motor rated torque = 79.58 × Motor capacity × Number of poles/Base frequency
Example: Motor rated torque = 79.58 × 5.5 (kW) × 4 (P)/50 (Hz) ≈ 35 Nm
*2. Data range varies depending on the data from [AH-04] to [AH-06].
*3. Data range varies depending on the data from [AJ-04] to [AJ-06].
*4. Data range varies depending on the data from [AJ-24] to [AJ-26].
*5. Data range varies depending on the data from [AJ-44] to [AJ-46].
8 - 180
Output scale range
Name
(Corresponding to 0 to 10 V /
0 to 20 mA / 0 to 100%)
-100.00 to 100.00(%)
-100.00 to 100.00(%)
-200.00 to 200.00(%)
-200.00 to 200.00(%)
-200.00 to 200.00(%)
-200.00 to 200.00(%)
-100.00 to 100.00(%)
-200.00 to 200.00(%)
-100.00 to 100.00(%)
-200.00 to 200.00(%)
-100.00 to 100.00(%)
-200.00 to 200.00(%)
0.00 to 100.00(%)
Output scale range
Name
(Corresponding to 0 to 10 V /
0 to 20 mA / 0 to 100%)
0.00 to 590.00(Hz)
0.00 to 590.00(Hz)
Motor rated torque ×
(-500.0 to 500.0(%))
Motor rated torque ×
(-500.0 to 500.0(%))
0.00 to 100.00(%)
0.00 to 100.00(%)
0.00 to 100.00(%)
0.00 to 100.00(%)
0.00 to 100.00(%)
0.00 to 100.00(%)
High-function General-purpose Inverter RX2 Series User's Manual
Remarks
*1
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Outputting is possible with (±).
Remarks
Outputting is possible with (±).
*1
Outputting is possible with (±).
*1
*2
*2
*2
*3
*4
*5