Omron RX2 Series User Manual page 435

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

 Parameter
Item
PID1 Feedback com-
pare signal turn-off
level
PID1 Feedback com-
pare signal turn-on
level
PID2 Feedback com-
pare signal turn-off
level
PID2 Feedback com-
pare signal turn-on
level
PID3 Feedback com-
pare signal turn-off
level
PID3 Feedback com-
pare signal turn-on
level
PID4 Feedback com-
pare signal turn-off
level
PID4 Feedback com-
pare signal turn-on
level
 Feedback Comparison Signal
Item
PID1 feedback com-
parison signal
PID2 feedback com-
parison signal
PID3 feedback com-
parison signal
PID4 feedback com-
parison signal
High-function General-purpose Inverter RX2 Series User's Manual
Terminal
Data
name
0.00 to
[AH-73]
100.00(%)
0.00 to
[AH-74]
100.00(%)
0.00 to
[AJ-18]
100.00(%)
0.00 to
[AJ-19]
100.00(%)
0.00 to
[AJ-38]
100.00(%)
0.00 to
[AJ-39]
100.00(%)
0.00 to
[AJ-58]
100.00(%)
0.00 to
[AJ-59]
100.00(%)
Terminal name
Data
[FBV1]
046
[FBV2]
048
[FBV3]
090
[FBV4]
092
Description
FBV1 signal output OFF judgment level
FBV1 signal output ON judgment level
FBV2 signal output OFF judgment level
FBV2 signal output ON judgment level
FBV3 signal output OFF judgment level
FBV3 signal output ON judgment level
FBV4 signal output OFF judgment level
FBV4 signal output ON judgment level
Description
PID1 feedback signal [FBV1]
OFF: Exceeded the OFF level.
ON: Went below the ON level.
PID2 feedback signal [FBV2]
OFF: Exceeded the OFF level.
ON: Went below the ON level.
PID3 feedback signal [FBV3]
OFF: Exceeded the OFF level.
ON: Went below the ON level.
PID4 feedback signal [FBV4]
OFF: Exceeded the OFF level.
ON: Went below the ON level.
8 Applied Settings
Default
data
100.00
0.00
100.00
0.00
100.00
0.00
100.00
0.00
8 - 35
8

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents