Operation with 3 Wire Function of Terminal Block

For 3-wire terminal commands, there are start, stop and forward/reverse operations. They are used to
start and stop the inverter via an automatic reset contact such as a pushbutton switch.
Operation start command can be given from [STA] terminal and stop command from [STP] terminal.
To use the 3 wire function, the setting of the Run-command input source selection, 1st-motor [AA111]
and the input terminal setting selection [CA-01]-[CA-11] needs to be changed.
Select [AA111]=01 3 wire function. In this example, the 3 wire function is assigned to the input terminal
function in the following way.
Input terminal
*1
A
9
[FR]
*1. Set the terminals as the terminal No. 7 [CA-07]=016, No. 8 [CA-08]=017, No. 9 [CA-09]=018.
Operation can be started/stopped by making the 016 [STA]/017 [STP] terminal function ON/OFF on the
control circuit terminal block of the inverter.
018 [F/R] terminal function switches forward and reverse rotations by the contact.
The terminal action is made in the following way.
STA
STP
F/R
Output
speed
High-function General-purpose Inverter RX2 Series User's Manual
Parameters
Data
[AA111]
00
01
[CA-01] to
[CA-11]
02
00
[CA-21] to
[CA-31]
01
*1
*1
8
7
COM
[STP]
[STA]
ON
OFF
ON
Forward
rotation
Reverse
rotation
6 Basic Parameter Settings
Description
Run/Stop from the control circuit terminal block.
([FW], [RV] terminals)
[FW] terminal function
[RV] terminal function
a contact (NO)
b contact (NC)
OFF
Default
data
*1
00
-
-
6
6 - 21

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents