Omron RX2 Series User Manual page 908

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Appendices C Table of Parameters
Codes that
can be
Code
changed
during
operation
Free-V/f Voltage 4 setting,
Hb257
-
2nd-motor
Free-V/f frequency 5 setting,
Hb258
-
2nd-motor
Free-V/f Voltage 5 setting,
Hb259
-
2nd-motor
Free-V/f frequency 6 setting,
Hb260
-
2nd-motor
Free-V/f Voltage 6 setting,
Hb261
-
2nd-motor
Free-V/f frequency 7 setting,
Hb262
-
2nd-motor
Free-V/f Voltage 7 setting,
Hb263
-
2nd-motor
Slip Compensation P-gain with
Hb270
encoder, 2nd-motor
Slip Compensation I-gain with
Hb271
encoder, 2nd-motor
Output voltage gain,
Hb280
2nd-motor(V/f)
*1. Varies depending on inverter models and settings of duty rating.
*2. It is a default value when Default Value Selection (Ub-02) is set to 01.
Codes that
can be
Code
changed
during
operation
Automatic torque boost voltage com-
HC101
pensation gain, 1st-motor
Automatic torque boost slip compensa-
HC102
tion gain, 1st-motor
Zero speed area limit for
HC110
Async.M-0SLV, 1st-motor
Boost value at start for
HC111
Async.M-SLV/IM-CLV, 1st-motor
Boost value at start for Async.M-0SLV,
HC112
1st-motor
Secondary resistance correction,
HC113
-
1st-motor
Counter direction run protection selec-
HC114
tion, 1st-motor
Torque current reference filter time con-
HC120
stant, 1st-motor
Speed feedforward compensation gain,
HC121
1st-motor
Automatic torque boost voltage com-
HC201
pensation gain, 2nd-motor
Automatic torque boost slip compensa-
HC202
tion gain, 2nd-motor
Zero speed area limit for
HC210
Async.M-0SLV, 2nd-motor
Boost value at start for
HC211
Async.M-SLV/IM-CLV, 2nd-motor
Boost value at start for Async.M-0SLV,
HC212
2nd-motor
Secondary resistance correction,
HC213
-
2nd-motor
Counter direction run protection selec-
HC214
tion, 2nd-motor
C - 60
Name
0.0 to 1000.0 (V)
[Hb256] to [Hb260] (Hz)
0.0 to 1000.0 (V)
[Hb258] to [Hb262] (Hz)
0.0 to 1000.0 (V)
[Hb260] to [Hb204] (Hz)
0.0 to 1000.0 (V)
0 to 1000 (%)
0 to 1000 (%)
0 to 255 (%)
Name
0 to 255 (%)
0 to 255 (%)
0 to 100 (%)
0 to 50 (%)
0 to 50 (%)
00 (Disabled)/01 (Enabled)
00 (Disabled)/01 (Enabled)
0 to 100 (ms)
0 to 1000
0 to 255 (%)
0 to 255 (%)
0 to 100 (%)
0 to 50 (%)
0 to 50 (%)
00 (Disabled)/01 (Enabled)
00 (Disabled)/01 (Enabled)
High-function General-purpose Inverter RX2 Series User's Manual
Data range
Data range
Initial value
Note
0.0
0.00
0.0
0.00
0.0
0.00
0.0
100
100
100
Initial
Note
value
100
100
80
0
10
00
00
2
0
100
100
80
0
10
00
00

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents