Omron RX2 Series User Manual page 430

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

8 Applied Settings
 Input Terminal Function
Item
PID2 disable function
PID2 I control integral
value clear
PID3 disable function
PID3 I control integral
value clear
PID4 disable function
PID4 I control integral
value clear
PID output switch 1
PID output switch 2
 Data Monitor Function
Item
PID2 target value
PID2 feedback monitor
PID2 output monitor
PID2 deviation monitor
PID3 target value
PID3 feedback monitor
PID3 output monitor
PID3 deviation monitor
PID4 target value
PID4 feedback monitor
PID4 output monitor
PID4 deviation monitor
*1. Data range varies depending on the data from [AJ-04] to [AJ-06].
*2. Data range varies depending on the data from [AJ-24] to [AJ-26].
*3. Data range varies depending on the data from [AJ-44] to [AJ-46].
8 - 30
Terminal name
Data
[PID2]
043
[PIDC2]
044
[PID3]
045
[PIDC3]
046
[PID4]
047
[PIDC4]
048
[PIO1]
056
[PIO2]
057
Parameter
Data
[FA-36]
-100.00 to 100.00(%)
[db-36]
-100.00 to 100.00(%)
[db-55]
-100.00 to 100.00(%)
[db-56]
-200.00 to 200.00(%)
[FA-38]
-100.00 to 100.00(%)
[db-38]
-100.00 to 100.00(%)
[db-57]
-100.00 to 100.00(%)
[db-58]
-200.00 to 200.00(%)
[FA-40]
-100.00 to 100.00(%)
[db-40]
-100.00 to 100.00(%)
[db-59]
-100.00 to 100.00(%)
[db-60]
-200.00 to 200.00(%)
High-function General-purpose Inverter RX2 Series User's Manual
Description
Disables the PID2 function by turning ON the termi-
nal function.
Frequency equivalent to the target value of PID2 will
be commanded when the terminal is turned ON.
Clears the integral value of PID2 control.
Disables the PID3 function by turning ON the termi-
nal function.
Frequency equivalent to the target value of PID3 will
be commanded when the terminal is turned ON.
Clears the integral value of PID3 control.
Disables the PID4 function by turning ON the termi-
nal function.
Frequency equivalent to the target value of PID4 will
be commanded when the terminal is turned ON.
Clears the integral value of PID4 control.
Switches PID output by a combination of PIO1 and
PIO2.
Description
Displays the target value of PID2.
*1
Changeable when [AJ-07] = 09.
*1
Displays the feedback value of PID2.
Displays the output value of PID2.
Displays the deviation of PID2.
Displays the target value of PID3.
*2
Changeable when [AJ-27] = 09.
*2
Displays the feedback value of PID3.
Displays the output value of PID3.
Displays the deviation of PID3.
Displays the target value of PID4.
*3
Changeable when [AJ-47] = 09.
*3
Displays the feedback value of PID4.
Displays the output value of PID4.
Displays the deviation of PID4.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents