Omron RX2 Series User Manual page 41

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Standard
operator keypad
Frequency
External
setting
signals
External port
Standard
Normal
operator keypad
rotation/
reverse
External
rotation
signals
Run/stop
External port
Input
Input terminal function
Backup power supply
terminal
STO input terminal
Thermistor input terminal
Output terminal function
Relay and alarm relay
Output
(16, AL)
EDM output terminal
Monitor output terminal
*9
EMC filter switching
External access to PC
Ambient temperature
Storage temperature
Use
environment
Humidity
*12
Vibration
*13
Use location
Expected Life time
*14
Applicable standards
Painting color
Operating, display
Number of option slots
Other options
*1. The output frequency range depend on the control and motor used. When running the inverter exceeding 60Hz, check the maximum allowable frequency
with the manufacturer of the motor.
High-function General-purpose Inverter RX2 Series User's Manual
Parameter setting using arrow keys
Ai1/Ai2 terminal (when changing voltage)
Ai1/Ai2 terminal (when changing current)
Ai3 terminal
*6
Multistage speed terminal
(use of input terminal function)
Pulse string input
(A/B terminal, use of input terminal function)
Setting via RS485 serial communication (protocol: Modbus-RTU)
Execution with the RUN /STOP key
(normal rotation/reverse rotation can be switched by setting parameters)
Normal rotation operation (FW)/reverse rotation (RV) (when an input terminal function is assigned)
3-wire input available (when an input terminal function is assigned)
Setting via RS485 serial communication (protocol: Modbus-RTU (maximum: 115.2kbps)
11 terminals (input of pulse string is available on terminal A and B)
FW (Normal rotation)/RV (Reverse rotation), CF1-4 (Multistage speed 1-4), SF1-7 (Multistage speed bit 1-7),
ADD (Addition of frequency), SCHG (Switching of frequency command), STA (3-wire start)/STP (3-wire
stop)/F_R (3-wire normal/reverse), AHD (Retention of analog command), FUP (Increase of speed via remote
operation/FDN (Deceleration via remote operation), UDC (Deletion of data via remote operation), F-OP (Forced
command switching), SET (Second control), RS (Reset), JG (Jogging), DB (External current braking), 2CH
(2-stage acceleration/deceleration), FRS (Free-run stop), EXT (External abnormality), USP (Prevention of restart
after restoration of power), CS (Commercial switching), SFT (Soft-lock), BOK (Brake check), OLR (Overload
restriction switching), KHC (Clearance of integrated input power), OKHC (Clearance of integrated output power),
PID (PID1 disabled), PIDC (PID1 integration reset), PID2 (PID2 disabled), PIDC2 (PID2 integration reset),
SVC1-4 (PID1 multistage target values 1-4), PRO (PID gain switching), PIO (PID output switching), SLEP
(SLEEP condition satisfied)/WAKE (WAKE condition satisfied), TL (Torque restriction enabled), TRQ1, 2
(Switching of torque limit 1,2), PPI (Switching of P/PI control), CAS (Switching of control gain), FOC (Preparatory
excitation), ATR (Torque control enabled), TBS (Torque bias enabled), LAC (Cancellation of
acceleration/deceleration), Mi1-11 (General-purpose input 1-11), PCC (Clearance of pulse counter), ECOM (Start
of EzCOM), PRG (Program run), HLD (Acceleration/deceleration stop), REN (Operation permission signal), PLA
(Pulse string input A), and PLB (Pulse string input B)
P+/P-: DC24V input (allowable input voltage: 24V±10%)
2 terminals (simultaneous input)
1 terminal (possible to switch between positive temperature coefficient/negative temperature coefficient
resistance element)
Transistor output 5 terminal, 1a contact relay 1 point, 1c contact relay 1 point
RUN (During operation), FA1-5 (Reached signal), IRDY (Operation ready completion), FWR (During normal
rotation operation), RVR (During reverse rotation operation), FREF (Frequency command operator keypad), REF
(Operation command operator keypad), SETM (Second control under selection), AL (Alarm signal), MJA (Severe
failure signal), OTQ (Over torque)
TRQ (During torque limitation), IPS (During power failure deceleration), RNT (RUN time over), ONT (Power on
time over), THM (Electronic thermal warning), THC (Electronic thermal warning), WAC (Capacitor life advance
notice), WAF (Fan life advance notice), FR (Operation command signal), OHF (Cooling fin heating advance
notice), LOC/LOC2 (Low-current signal), OL/OL2 (Overload advance notice), BRK (Brake release), BER (Brake
abnormality), ZS (Zero-speed detection signal), OD/OD2 (PID deviation excessive), FBV/FBV2 (PID feedback
comparison), NDc (Communication disconnection), Ai1Dc/Ai2Dc/Ai3Dc (Analog disconnection Ai1/Ai2/Ai3),
WCAi1/WCAi2/WCAi3 (Window comparator Ai1/Ai2/Ai3), LOG1-7 (Logical operation result 1-7), MO1-7 (General
output 1-7), and OVS (Receiving overvoltage).
Output for STO diagnosis
*8
Possible to output through selection from monitor data of parameters
Possible to enable the EMC noise filter (switching method is different depending on the model)
USB Micro-B
ND (normal duty)
-10 to 50°C
*10
LD (low duty)
-10 to 45°C
VLD (very low duty)
-10 to 40°C
*11
-20 to 65°C
20-90%RH (location free of condensation)
2
5.9m/s
(0.6G) 10 to 55Hz: 3G3RX2-A2004 to A2220/3G3RX2-A4007 to A4220
2
2.94m/s
(0.3G) 10 to 55Hz: 3G3RX2-A2300 to A2550/3G3RX2-A4300 to A413K
1000 m altitude or lower (location free from corrosive gas, oil mist, and dust)
Smoothing capacitor 10 years
Designed life of cooling fan 10 years (models equipped with a cooling fan) free from dust
Memory element on the control circuit board
Compliance with UL/cUL/CE standards, RCM, Functional Safety SIL3/PLe
Black
*15
LCD Operator
3 ports
Braking resistor, AC reactor, DC reactor, noise filter
Setting through input of 0 to 10VDC voltage (input impedance:
10kΩ)
Setting through input of 0 to 20mA current (input impedance:
100Ω)
Setting through input of -10 to +10V voltage (input impedance:
10kΩ)
15 speed
32kHz×2 at maximum
*7
, IP (During instantaneous power failure), UV (Under insufficient voltage),
1 Overview
1
1 - 9

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents