Parameter Function

3-8-1

Parameter Preservation Function

By configuring the soft-lock function you can prevent parameters from being changed.
STOP
Output Frequency
UA-16
Soft-Lock Selection
01: Always enabled
Menu
oFW
 Parameters
Item
Soft-lock selection
Soft-lock target
selection
Input terminal
selection
High-function General-purpose Inverter RX2 Series User's Manual
H03
M1
0.00 Hz
LKS
Optional
60.00Hz
device
Parameter
Data
[UA-16]
00
01
[UA-17]
00
01
[CA-01] to
036
[CA-11]
By configuring the soft-lock function [UA-16] and [UA-17], you
can prevent parameters from being changed.
While soft-lock function is enabled, the LKS mark (Lock State
mark)
is shown on the right of parameters.
LKS
Description
Normal state.
Only when the soft-lock terminal [SFT] is on, data set to
[UA-17] other than [UA-16] are locked.
After the setting is performed, the data set to [UA-17] other
than [UA-16] are locked.
All data other than [UA-16] cannot be changed
Data other than [UA-16] and set frequency cannot be changed
[SFT]: Used when the soft-lock function is used on terminals.