2 Design
Mounting of 3G3RX2-A2220:
1
Fix the four spacers to the main body at the fittings both on the top and bottom using four M3×8
screws included in the pack (Torque: 0.6 to 0.8 N·m).
2
Fix the main body on the wall with four other screws you provide.
Step 2
Screws you
provide
Step 2
Screws you
provide
Precautions for Correct Use
Set [Ub-03]=00 for Very Light Duty (VLD)
2 - 6
Step 1
Screw M3 × 8
Screw M3 × 8
Mounting method
Step 1
Spacer
Step 1
Spacer
Right side view
High-function General-purpose Inverter RX2 Series User's Manual
Wall
Wall