2 Design
Derating of Rated Output Current
Please use the inverter within the current range in accordance with the derating tables of respective
models. If you use the inverter exceeding the derating range, note that the inverter may be damaged or
its life may be shortened.
 200 V class
3G3RX2-A2004/A2007/A2015/A2022 Derating is not required.
• 3G3RX2-A2037
25
20
17.5A
15
10
0
2
4
6
Carrier frequency (kHz)
• 3G3RX2-A2075
50
45
40
40A
35
30
25
26A
20
15
10
0
2
4
6
Carrier frequency (kHz)
2 - 10
50°C: ND rating (normal duty rating)
45°C: LD rating (low duty rating)
40°C: VLD rating (very low duty rating)
22.8A
19.6A
16A
14A
8
10
12
14
16
18
46A
32A
29A
22A
8 10 12 14 16 18
• 3G3RX2-A2055
35
30
25
20
15
0
2
4
• 3G3RX2-A2110
65
60
55
50
45
40
35
30
25
20
15
0
2
4
Carrier frequency (kHz)
High-function General-purpose Inverter RX2 Series User's Manual
33A
30A
25A
22A
6
8
10 12 14 16 18
Carrier frequency (kHz)
VLD:60A
LD:56A
46A
35A
31A
22A
6
8
10
12
14
16
18