Omron RX2 Series User Manual page 428

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

8 Applied Settings
Item
PID2 derivative gain
PID3 enable
PID3 deviation inverse
Input source selection
of Set-point for PID3
Set-point setting for
PID3
Input source selection
of Process data for
PID3
PID3 proportional gain
PID3 integral time con-
stant
PID3 derivative gain
*1. Data range varies depending on the data from [AJ-04] to [AJ-06].
*2. Data range varies depending on the data from [AJ-24] to [AJ-26].
8 - 28
Parameter
Data
0.00 to
[AJ-15]
100.00(s)
00
01
[AJ-21]
02
00
[AJ-22]
01
[AJ-27]
00 to 13
0.00 to
[AJ-30]
*2
100.00(%)
[AJ-32]
00 to 13
[AJ-33]
0.0 to 100.0
[AJ-34]
0.0 to 3600.0(s) Integral gain
0.00 to
[AJ-35]
100.00(s)
High-function General-purpose Inverter RX2 Series User's Manual
Description
Differential gain
Disable
Enable (if command becomes negative, it
does not output in a reverse direction)
Enable (if command becomes negative, it
outputs in a reverse direction)
Disable
Enabled (polarity inversion of deviation)
00: Disable, 01: Ai1-L input, 02: Ai2-L input,
03: Ai3-L input, 04: (Reserved),
05: (Reserved), 06: (Reserved),
07: Parameter setting [AH-44],
08: RS 485 communication, 09: Option 1,
10: Option 2, 11: Option 3,
12: Pulse train input (main unit),
13: Pulse train input (option)
Is a parameter set value.
00: Disable, 01: Ai1-L input, 02: Ai2-L input,
03: Ai3-L input, 04: (Reserved),
05: (Reserved), 06: (Reserved),
07: Parameter setting [AH-44],
08: RS 485 communication, 09: Option 1,
10: Option 2, 11: Option 3,
12: Pulse train input (main unit),
13: Pulse train input (option)
Proportional gain
Differential gain
Default
data
0.00
00
00
07
0.00
02
1.0
1.0
0.00

Hide quick links: