Phase Coefficient Monitoring Mode
Input terminals [A] and [B] become available for pulse string inputs.
(a) Mode 0: [CA-91]=00 90° Phase difference pulse string
Pulse string input
Terminal [A]
Pulse string input
Terminal [B]
Number of detected pulses
(b) Mode 1: [CA-91]=01 Normal and reverse rotation instruction + Pulse string
Pulse string
input
Normal and
reverse rotation
instruction
Number of detected pulses
(c) Mode 2: [CA-91]=02 Normal rotation pulse string + Reverse rotation pulse string
Normal rotation
pulse string input
Reverse rotation
pulse string input
Number of detected pulses
High-function General-purpose Inverter RX2 Series User's Manual
Terminal [A]
Terminal [B]
Terminal [A]
Terminal [B]
Negative (-)
Positive (+)
Positive (+)
Negative (-)
Positive (+)
Negative (-)
8 Applied Settings
Time
Time
Time