9 Communications Functions
Modbus
Register
register
No.
spec. No.
run command enable option
3E8Dh
3E8Ch
during the option card
(SLOT-1) start-up
Operation mode on option
3E94h
3E93h
card error (SLOT-2)
Communication Watch Dog
3E95h
3E94h
Timer
Action selection at communi-
3E96h
3E95h
cation error
run command enable option
3E97h
3E96h
during the option card
(SLOT-2) start-up
Operation mode on option
3E9Eh
3E9Dh
card error (SLOT-3)
Communication Watch Dog
3E9Fh
3E9Eh
Timer
Action selection at communi-
3EA0h
3E9Fh
cation error
run command enable option
3EA1h
3EA0h
during the option card
(SLOT-3) start-up
3EE5h
3EE4h
Encoder constant setting
3EE6h
3EE5h
Encoder position selection
3EE7h
3EE6h
Motor gear ratio Numerator
3EE8h
3EE7h
Motor gear ratio Denominator
Pulse train detection object
3EEEh
3EEDh
selection
Mode selection of pulse train
3EEFh
3EEEh
input
3EF0h
3EEFh
Pulse train frequency Scale
Pulse train frequency Filter
3EF1h
3EF0h
time constant
Pulse train frequency Bias
3EF2h
3EF1h
value
Pulse train frequency High
3EF3h
3EF2h
Limit
Pulse train frequency detec-
3EF4h
3EF3h
tion low level
9 - 96
Parameter
Function name
No.
oA-13
oA-20
oA-21
oA-22
oA-23
oA-30
oA-31
oA-32
oA-33
ob-01
ob-02
ob-03
ob-04
ob-10
ob-11
ob-12
ob-13
ob-14
ob-15
ob-16
High-function General-purpose Inverter RX2 Series User's Manual
R/W
Monitor or setting data
00: Operation command disabled
R/W
01: Operation command enabled
00: Error
R/W
01: Continue operation
R/W
0 to 10000
00: Error
01: Trip after deceleration stop
R/W
02: Ignore
03: Free run
04: Deceleration stop
00 (Operation command dis-
R/W
abled)/
01 (Operation command enabled)
00: Error
R/W
01: Continue operation
R/W
0 to 10000
00: Error
01: Trip after deceleration stop
R/W
02: Ignore
03: Free run
04: Deceleration stop
00: Operation command disabled
R/W
01: Operation command enabled
R/W
32 to 65535
00: Phase-A is leading
R/W
01: Phase-B is leading
R/W
1 to 10000
R/W
1 to 10000
00: Command
R/W
01: Pulse string position com-
mand
00: 90° phase difference
01: forward/reverse rotation com-
R/W
mand and rotation direction
02: forward/reverse rotation pulse
string
R/W
5 to 20000
R/W
1 to 200
R/W
-1000 to 1000
R/W
0 to 1000
R/W
0 to 1000
Resolution
-
-
0.01(s)
-
-
-
0.01(s)
-
-
1(pls)
-
1
1
-
-
0.01
(kHz)
0.01(s)
0.1(%)
0.1(%)
0.1(%)