9 Communications Functions
Modbus
Register
register
No.
spec. No.
Selection of restart mode
334Ah
3349h
@over-voltage
Wait time of restart
334Bh
334Ah
@over-voltage
Restart mode after FRS
3354h
3353h
release
Restart mode after RS
3355h
3354h
release
3356h
3355h
Restart frequency threshold
Restart level of Active fre-
3357h
3356h
quency matching
Restart constant(speed) of
3358h
3357h
Active frequency matching
Restart constant(Voltage) of
3359h
3358h
Active frequency matching
OC-supress level of Active
335Ah
3359h
frequency matching
Restart speed selection of
335Bh
335Ah
Active frequency matching
Over current detection level,
3368h
3367h
1st-motor
Power supply over voltage
3369h
3368h
selection
Power supply over voltage
336Ah
3369h
level setting
336Ch
336Bh
Ground fault selection
336Dh
336Ch
Input phase loss enable
336Eh
336Dh
Output phase loss enable
Output phase loss detection
336Fh
336Eh
sensitivity
3372h
3371h
Thermistor error level
337Ch
377Bh
Over speed detection level
337Dh
337Ch
Over speed detection time
Speed deviation error mode
337Eh
337Dh
selection
Speed deviation error detec-
337Fh
337Eh
tion level
Speed deviation error detec-
3380h
337Fh
tion time
Position deviation error mode
3381h
3380h
selection
9 - 68
Parame-
Function name
ter No.
bb-30
bb-31
bb-40
bb-41
bb-42
bb-43
bb-44
bb-45
bb-46
bb-47
bb160
bb-61
bb-62
bb-64
bb-65
bb-66
bb-67
bb-70
bb-80
bb-81
bb-82
bb-83
bb-84
bb-85
High-function General-purpose Inverter RX2 Series User's Manual
R/W
Monitor or setting data
00: 0Hz
01: Frequency matching
02: Frequency entrainment
R/W
03: Detection speed
04: Trip after frequency matching
deceleration stop
R/W
0.3 to 100.0 (s)
00: 0Hz
01: Frequency matching
R/W
02: Frequency entrainment
03: Detection speed
00: 0Hz
01: Frequency matching
R/W
02: Frequency entrainment
03: Detection speed
R/W
0 to 59000
(0.0 to 2.0)
R/W
× Inverter rated current
R/W
10 to 3000
R/W
10 to 3000
(0.0 to 2.0)
R/W
× Inverter rated current
00: Cutoff frequency
R/W
01: Maximum frequency
02: Setting frequency
(0.2 to 2.2)
R/W
x Inverter ND rated current
00: Warning
R/W
01: Error
(200V class) 3000 - 4100
R/W
(400V class) 6000 - 8200
00: Disabled
R/W
01: Enabled
00: Disabled
R/W
01: Enabled
00: Disabled
R/W
01: Enabled
R/W
1 to 100
R/W
0 to 10000
R/W
0 to 1500
R/W
0 to 50
00: Warning
R/W
01: Error
R/W
0 to 1000
R/W
0 to 50
00: Warning
R/W
01: Error
Resolution
-
0.1(s)
*4
-
*4
0.01(Hz)
0.1(A)
*1
0.01(s)
0.01(s)
0.1(A)
*1
-
0.1(A)
*1
-
0.1(Vdc)
-
-
-
1(%)
1(Ω)
0.1(%)
0.1(s)
-
0.1(%)