Omron RX2 Series User Manual page 877

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Codes that
can be
Code
changed
during
operation
Braking Frequency, 2nd-motor
AF244
(Reverse side)
AF250
Brake open delay time, 2nd-motor
AF251
Brake close delay time, 2nd-motor
Brake answer back check time,
AF252
2nd-motor
Servo lock/ DC injection time at
AF253
start, 2nd-motor
Servo lock/ DC injection time at
AF254
stop, 2nd-motor
*1. On the parameter about the current and the voltage, the figures and the units to be handled vary in the setting path.
1) Operator or CX-Drive: 0.1 A or 0.1 V (When CX-Drive is operated, set [CF-11] Resister data selection to 00 (A,V). When the data of
[CF-11] Resister data selection is not set to 00 (A,V), it is not set or displayed correctly.)
2) Modbus: The current and the voltage vary, depending on the setting of Resister data selection [CF-11].
When [CF-11] Resister data selection is set to 00 (A,V), 0.1 A, 0.1 V
When [CF-11] Resister data selection is set to 01 (%), 0.01% (Rated ratio)
3) Drive programming: 0.01% (Rated ratio)
Codes that
can be
Code
changed
during
operation
AG101
Jump frequency 1, 1st-motor
AG102
Jump frequency width 1, 1st-motor 0.00 to 10.00 (Hz)
AG103
Jump frequency 2, 1st-motor
AG104
Jump frequency width 2, 1st-motor 0.00 to 10.00 (Hz)
AG105
Jump frequency 3, 1st-motor
AG106
Jump frequency width 3, 1st-motor 0.00 to 10.00 (Hz)
Acceleration stop frequency set-
AG110
ting, 1st-motor
Acceleration stop time setting,
AG111
1st-motor
Deceleration stop frequency set-
AG112
ting, 1st-motor
Deceleration stop time setting,
AG113
1st-motor
AG-20
Jogging frequency
AG-21
-
Jogging stop mode selection
AG201
Jump frequency 1, 2nd-motor
Jump frequency width 1,
AG202
2nd-motor
AG203
Jump frequency 2, 2nd-motor
Jump frequency width 2,
AG204
2nd-motor
AG205
Jump frequency 3, 2nd-motor
Jump frequency width 3,
AG206
2nd-motor
Acceleration stop frequency set-
AG210
ting, 2nd-motor
Acceleration stop time setting,
AG211
2nd-motor
Deceleration stop frequency set-
AG212
ting, 2nd-motor
High-function General-purpose Inverter RX2 Series User's Manual
Name
0.00 to 590.00 (Hz)
0.00 to 2.00 (s)
0.00 to 2.00 (s)
0.00 to 5.00 (s)
0.00 to 10.00 (s)
0.00 to 10.00 (s)
Name
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.0 to 60.0 (s)
0.00 to 590.00 (Hz)
0.0 to 60.0 (s)
0.00 to 10.00 (Hz)
00 (Disabled during FRS operation at stop)/
01 (Disabled during deceleration stop operation)/
02 (Disabled during DB operation at stop)/
03 (Enabled during FRS operation at stop)/
04 (Enabled during deceleration stop operation)/
05 (Enabled during DB operation at stop)
0.00 to 590.00 (Hz)
0.00 to 10.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 10.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 10.00 (Hz)
0.00 to 590.00 (Hz)
0.0 to 60.0 (s)
0.00 to 590.00 (Hz)
Appendices C Table of Parameters
Data range
Data range
Initial value
Note
0.00
0.20
0.20
0.10
0.60
0.60
Initial
Note
value
0.00
0.00
0.00
0.00
0.00
0.00
C
0.00
0.0
0.00
0.0
6.00
00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.0
0.00
C - 29

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents