Codes that
can be
Code
changed
during
operation
Braking Frequency, 2nd-motor
AF244
○
(Reverse side)
AF250
○
Brake open delay time, 2nd-motor
AF251
○
Brake close delay time, 2nd-motor
Brake answer back check time,
AF252
○
2nd-motor
Servo lock/ DC injection time at
AF253
○
start, 2nd-motor
Servo lock/ DC injection time at
AF254
○
stop, 2nd-motor
*1. On the parameter about the current and the voltage, the figures and the units to be handled vary in the setting path.
1) Operator or CX-Drive: 0.1 A or 0.1 V (When CX-Drive is operated, set [CF-11] Resister data selection to 00 (A,V). When the data of
[CF-11] Resister data selection is not set to 00 (A,V), it is not set or displayed correctly.)
2) Modbus: The current and the voltage vary, depending on the setting of Resister data selection [CF-11].
When [CF-11] Resister data selection is set to 00 (A,V), 0.1 A, 0.1 V
When [CF-11] Resister data selection is set to 01 (%), 0.01% (Rated ratio)
3) Drive programming: 0.01% (Rated ratio)
Codes that
can be
Code
changed
during
operation
AG101
○
Jump frequency 1, 1st-motor
AG102
○
Jump frequency width 1, 1st-motor 0.00 to 10.00 (Hz)
AG103
○
Jump frequency 2, 1st-motor
AG104
○
Jump frequency width 2, 1st-motor 0.00 to 10.00 (Hz)
AG105
○
Jump frequency 3, 1st-motor
AG106
○
Jump frequency width 3, 1st-motor 0.00 to 10.00 (Hz)
Acceleration stop frequency set-
AG110
○
ting, 1st-motor
Acceleration stop time setting,
AG111
○
1st-motor
Deceleration stop frequency set-
AG112
○
ting, 1st-motor
Deceleration stop time setting,
AG113
○
1st-motor
AG-20
○
Jogging frequency
AG-21
-
Jogging stop mode selection
AG201
○
Jump frequency 1, 2nd-motor
Jump frequency width 1,
AG202
○
2nd-motor
AG203
○
Jump frequency 2, 2nd-motor
Jump frequency width 2,
AG204
○
2nd-motor
AG205
○
Jump frequency 3, 2nd-motor
Jump frequency width 3,
AG206
○
2nd-motor
Acceleration stop frequency set-
AG210
○
ting, 2nd-motor
Acceleration stop time setting,
AG211
○
2nd-motor
Deceleration stop frequency set-
AG212
○
ting, 2nd-motor
High-function General-purpose Inverter RX2 Series User's Manual
Name
0.00 to 590.00 (Hz)
0.00 to 2.00 (s)
0.00 to 2.00 (s)
0.00 to 5.00 (s)
0.00 to 10.00 (s)
0.00 to 10.00 (s)
Name
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 590.00 (Hz)
0.0 to 60.0 (s)
0.00 to 590.00 (Hz)
0.0 to 60.0 (s)
0.00 to 10.00 (Hz)
00 (Disabled during FRS operation at stop)/
01 (Disabled during deceleration stop operation)/
02 (Disabled during DB operation at stop)/
03 (Enabled during FRS operation at stop)/
04 (Enabled during deceleration stop operation)/
05 (Enabled during DB operation at stop)
0.00 to 590.00 (Hz)
0.00 to 10.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 10.00 (Hz)
0.00 to 590.00 (Hz)
0.00 to 10.00 (Hz)
0.00 to 590.00 (Hz)
0.0 to 60.0 (s)
0.00 to 590.00 (Hz)
Appendices C Table of Parameters
Data range
Data range
Initial value
Note
0.00
0.20
0.20
0.10
0.60
0.60
Initial
Note
value
0.00
0.00
0.00
0.00
0.00
0.00
C
0.00
0.0
0.00
0.0
6.00
00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.0
0.00
C - 29