Omron RX2 Series User Manual page 906

High-function general-purpose inverter
Hide thumbs Also See for RX2 Series:
Table of Contents

Advertisement

Appendices C Table of Parameters
Codes that
can be
Code
changed
during
operation
Async.Motor capacity setting,
Hb102
-
1st-motor
Async.Motor Maximum fre-
Hb105
-
quency setting, 1st-motor
Async.Motor rated voltage,
Hb106
-
1st-motor
Async.Motor rated current,
Hb108
-
1st-motor
Async.Motor constant R1,
Hb110
-
1st-motor
Async.Motor constant R2,
Hb112
-
1st-motor
Async.Motor constant L,
Hb114
-
1st-motor
Async.Motor constant Io,
Hb116
-
1st-motor
Async.Motor constant J,
Hb118
-
1st-motor
Minimum frequency adjust-
Hb130
-
ment, 1st-motor
Reduced voltage start time set-
Hb131
ting, 1st-motor
Manual torque boost opera-
Hb140
-
tional mode selection, 1st-motor
Manual torque boost value,
Hb141
1st-motor
Manual torque boost Peak
Hb142
speed, 1st-motor
Hb145
-
Eco drive enable, 1st-motor
Eco drive response adjustment,
Hb146
1st-motor
Free-V/f frequency 1 setting,
Hb150
-
1st-motor
Free-V/f Voltage 1 setting,
Hb151
-
1st-motor
Free-V/f frequency 2 setting,
Hb152
-
1st-motor
Free-V/f Voltage 2 setting,
Hb153
-
1st-motor
Free-V/f frequency 3 setting,
Hb154
-
1st-motor
Free-V/f Voltage 3 setting,
Hb155
-
1st-motor
Free-V/f frequency 4 setting,
Hb156
-
1st-motor
Free-V/f Voltage 4 setting,
Hb157
-
1st-motor
Free-V/f frequency 5 setting,
Hb158
-
1st-motor
Free-V/f Voltage 5 setting,
Hb159
-
1st-motor
Free-V/f frequency 6 setting,
Hb160
-
1st-motor
Free-V/f Voltage 6 setting,
Hb161
-
1st-motor
C - 58
Name
0.01 to 160.00 (kW)
10.00 to 590.00 (Hz)
1 to 1000 (V)
0.01 to 10000.00 (A)
0.000001 to 1000.000000 (Ω)
0.000001 to 1000.000000 (Ω)
0.000001 to 1000.000000 (mH)
0.01 to 10000.00 (A)
0.00001 to 10000.00000 (kgm
0.10 to 10.00 (Hz)
0 to 2000 (ms)
00 (Disabled)/
01 (Always enabled)/
02 (Enabled only for forward revolution)/
03 (Enabled only for reverse revolution)
0.0 to 20.0 (%)
0.0 to 50.0 (%)
00 (Disabled)/01 (Enabled)
0.0 to 100.0(%)
0.00 to [Hb152] (Hz)
0.0 to 1000.0 (V)
[Hb150] to [Hb154] (Hz)
0.0 to 1000.0 (V)
[Hb152] to [Hb156] (Hz)
0.0 to 1000.0 (V)
[Hb154] to [Hb158] (Hz)
0.0 to 1000.0 (V)
[Hb156] to [Hb160] (Hz)
0.0 to 1000.0 (V)
[Hb158] to [Hb162] (Hz)
0.0 to 1000.0 (V)
High-function General-purpose Inverter RX2 Series User's Manual
Data range
2
)
Initial value
Note
*1
*2
50.00
200 V class: 230
*2
400 V class: 400
460 (*FUF)
*1
*1
*1
*1
*1
*1
0.50
36
01
0.0
0.0
00
50.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0
0.00
0.0

Hide quick links: