No.
Name
Screen for selecting the location for reading data that is downloaded using the R/W
21
function
22
Screen for displaying progress status of downloading using the R/W function
23
System settings screen
24
Language selection screen
25
Dimming setting screen
26
Setting screen for automatic light off time
27
Setting screen for dimming at light off
28
Setting screen for automatic home transition time
29
Monitor screen for basic inverter information
30
Selection screen for operator initialization
31
Operator version display screen
32
Date and time screen
33
Date and time setting screen
34
Selection screen for date and time display format
35
Setting screen for battery level warning
36
Inverter model selection screen
37
Read lock selection screen
38
Selection screen for blinking at the time of trip
39
Color setting screen
40
Selection screen for self-check mode
41
Setting screen for automatic home screen
42
Remote mode switching screen
43
Scroll menu
44
Scroll screen
Message screen
45
*1. If a message is displayed, see 12-3-3 Checking Message on page 12-30.
Display <e>: STO Function Display
No.
Display
e1
(None)
e2
P-1A
e3
P-2A
e4
P-1b
e5
P-2b
e6
P-1C
High-function General-purpose Inverter RX2 Series User's Manual
Operation of ST1 and ST2 are both enabled (contact point ON), the inverter's output motion
is also enabled.
From the status that the operation of ST1 and ST2 are both enabled (contact point ON),
only ST2 transitions to STO (contact point OFF) and later ST1 is kept operation-enabled
(contact point ON) for the STO switching allowable time [bd-02].
From the status that the operation of ST1 and ST2 are both enabled (contact point ON),
only ST1 transitions to STO (contact point OFF) and later ST2 is kept operation-enabled
(contact point ON) for the STO switching allowable time [bd-02].
(1) The status of P-1A or P-1b continued for the STO switching allowable time [bd-02].
(2) At the status that the operation of ST1 and ST2 were both enabled (contact point ON),
only ST2 transitioned to STO (contact point OFF) and later the operation was allowed (con-
tact point ON).
(1) The status of P-2A or P-2b continued for the STO switching allowable time [bd-02].
(2) At the status that the operation of ST1 and ST2 were both enabled (contact point ON),
only ST1 transitioned to STO (contact point OFF) and later the operation was allowed (con-
tact point ON).
From the status that the operation of ST1 and ST2 are both STO (contact point OFF), ST2
transitions to be operation-allowed (contact point ON), and later ST1 is kept STO (contact
point OFF) for the STO switching allowable time [bd-02].
Description
3 Operation
Screen
number
R06
R07
S01
S02
S03
S04
S05
S06
S07
S08
S09
S11
3
S12
S13
S14
S19
S21
S22
S23
S25 to S35
S36
S38
L01
L02
*1
3 - 9