8 Applied Settings
 Input Terminal Function
Item
PID disable function
PID1 I control inte-
gral value clear
Multi-layer target
command terminal 1
Multi-layer target
command terminal 2
Multi-layer target
command terminal 3
Multi-layer target
command terminal 4
PID gain switch
 Data Monitor Function
Item
PID1 target value 1
PID1 target value 2
PID1 target value 3
PID1 feedback data 1
monitor
PID1 feedback data 2
monitor
PID1 feedback data 3
monitor
PID1 target value monitor
after calculation
PID1 feedback data
PID1 output monitor
PID1 deviation monitor
PID1 deviation 1 monitor
PID1 deviation 2 monitor
PID1 deviation 3 monitor
PID current P gain monitor
PID current I gain monitor
PID current D gain monitor
PID feed-forward monitor
*1. Data range varies depending on the data from [AH-04] to [AH-06].
8 - 10
Terminal name
Data
[PID]
041
[PIDC]
042
[SVC1]
051
[SVC2]
052
[SVC3]
053
[SVC4]
054
[PRO]
055
Parameter
[FA-30]
0.00 to 100.00(%)
[FA-32]
0.00 to 100.00(%)
[FA-34]
0.00 to 100.00(%)
[db-30]
-100.00 to 100.00(%)
[db-32]
-100.00 to 100.00(%)
[db-34]
-100.00 to 100.00(%)
[db-42]
-100.00 to 100.00(%)
[db-44]
-100.00 to 100.00(%)
[db-50]
-100.00 to 100.00(%)
[db-51]
-200.00 to 200.00(%)
[db-52]
-200.00 to 200.00(%)
[db-53]
-200.00 to 200.00(%)
[db-54]
-200.00 to 200.00(%)
[db-61]
0.0 to 100.0
[db-62]
0.0 to 3600.0(s)
[db-63]
0.00 to 100.00(s)
[db-64]
-100.00 to 100.00(%)
High-function General-purpose Inverter RX2 Series User's Manual
Description
Disables the PID1 function by turning ON the terminal
function. When disabled, operation is done by using
the command set for target value as command fre-
quency.
Clears integral value of PID1 control.
Switches multiple target values.
Switches PID gain 1 and 2 by terminal.
Data
Displays PID1 target value.
*1
Is changeable when [AH-07] = 07 or
multi-layer target value 1-15 is enabled.
Displays PID1 target value 2.
*1
Is changeable when [AH-42] = 07.
Displays PID1 target value 3.
*1
Is changeable when [AH-46] = 07.
*1
Displays PID1 feedback value 1.
*1
Displays PID1 feedback value 2.
*1
Displays PID1 feedback value 3.
Displays target value after calculation by
*1
[AH-50].
Displays feedback value after calculation
*1
by [AH-54].
Displays PID1 output value.
Displays PID1 deviation.
Monitors 3 deviations of PID1 when
[AH-50] = 05 or 06.
Displays current P gain.
Displays current I gain.
Displays current D gain.
Displays feed-forward command value.
Description