Goodrive35 inverters
Function
code
P06.05
Polarity of output terminals
P06.06
Y1 switch-on delay time
P06.07
Y1 switch-off delay time
P06.08
HDO switch-on delay
P06.09
HDO switch-off delay
P06.10
RO1 switch-on delay
P06.11
RO1 switch-off delay
P06.12
RO2 switch-on delay
P06.13
RO2 switch-off delay
P07.38
Max temperature at present fault
P17.13
Digital output terminals state
7.13 Simple PLC
Simple PLC function is also a multi-step speed generator. The inverter can change the running
frequency, direction to meet the need of processing according to the running time automatically. In the
past, this function needs to be assisted by external PLC, but now the inverter can realize this function
by itself.
The series inverters can control 16-stage speed with 4 groups of ACC/DEC time.
The multi-function digital output terminals or multi-function relay output an ON signal when the set
PLC finishes a circle (or a stage).
P10.00(simle PLC)
Stop after
0
running one time
1
Run at the final
value after
running for one
time
2
Cycle
PLC method
Digital output 15
Simple PLC stage
completion
Digital output 20
Simple PLC cycle
completion
Name
P10.01 (simple PLC memory selection)
Power off during
running
Running
parameter setting
in all stages in
PLC
Normal running
200ms
Detailed instruction of parameters
35: Reserved
36: Speed/position switching finished
37 – 40: Reserved
0x00 – 0x0F
0.000 – 50.000 s
0.000 – 50.000 s
0.000 – 50.000 s
(valid only when P06.00=1)
0.000 – 50.000 s
(valid only when P06.00=1)
0.000 – 50.000 s
0.000 – 50.000 s
0.000 – 50.000 s
0.000 – 50.000 s
0
Power off
without memory
1
Power off with
memory
0
1
P10.36
(PLC starting selection)
171
Basic operation instruction
Restart from the
first stage
0
Restart form the
1
frequency of the
pause stage
Terminal function 23
Simple PLC stop reset
200ms
Default
value
0x00
0.000 s
0.000 s
0.000 s
0.000 s
0.000 s
0.000 s
0.000 s
0.000 s
0
0
Set frequency
P17.00